21
F U N C T I O N M E N U
Display RF Transmitter Status?
(OPTIONAL)
(For systems that include wireless trans-
mitters).
Press YES to check the status and condition of all transmitters. First the number
of wireless points (WL PNT) will display. Use NEXT and PRIOR Buttons to scroll forward or
back. For each transmitter, the following information will be shown:
•
Transmitter ID Code number (6 numbers and/or letters).
•
Zone ("z”) to which transmitter is mapped and signal strength "s" (01—10, 10 being the
strongest) of its last transmission.
A display of "Z01BAT"
(battery)
indicates that the transmitter on Zone 1 has a battery that is
weak and requires replacement.
A display of "Z01TAM" (tamper condition) indicates that the case of the transmitter on Zone
1 is open.
A display of "Z01SUP"
(supervisory
failure) indicates that a test signal from the transmitter
on Zone 1 has not been received.
Note:
Hold down
G
to recall the first line.
Relay Control?
(OPTIONAL) Turns on (or off) one or more programmed Relay Groups.
Press
U
to turn the displayed group on or off; press NEXT to proceed to the next group, or
PRIOR to scroll back to the previous group. Press
C
when done. (Hold down
G
to
view the "description" line. (This function available for the GEM-P9600/3200 panels only).
A C O N
R F X m t / S t a t u s /
Y e s / N o
A C O N
1 2 3 4 5 6 /
Z 0 1 S 1 0
A C O N
1 2 3 4 5 6 /
Z 0 1 B A T
A C O N
1 2 3 4 5 6 /
Z 0 1 T A M
A C O N
1 2 3 4 5 6 /
Z 0 1 S U P
A C O N
R e l a y / C t r l /
Y e s / N o
A C O N
R G - O F F /
( D E S C R I P T I O N )
Summary of Contents for Gemini GEM-K2AS
Page 24: ...24 NOTES...