NAPCO Gemini C
-
Series Control Panel Programming Instructions
--
Volume 2
NAPCO Security Group
Programming Instructions, Volume 2
Page 101
SYSTEM OPTIONS (ADDRESS 5328-5329)
SYSTEM OPTIONS:
1.
Select System Options from the tables shown and enter in the corresponding address location at right.
2.
Press
U
to save.
NOTE:
Dark shaded data value box shows option not available.
*Note:
Address 5328 Option 8
Keypad Blanking
clears all data from the LCD display (and turns off all keypad LED's) after the
system is armed and delay time has expired. The display will re
-
appear when an exit/entry door is faulted, causing an entry time
delay display, or if a valid user code is entered at the keypad while the system is armed.
ADDRESS 5328
SYSTEM OPTIONS
DATA ENTRIES
RIGHT
OPTION
1
Enable ACM Access
2
Access Log to 6000 Events
3
Enable TCP/IP Communications
4
TCP/IP Panel/Site Initiated Functions
5
Disable H/A Keypad Display
6
RESERVED
7
Enable EURO Features
8
Enable Keypad Blanking*
ADDRESS 5329
SYSTEM OPTIONS
DATA
ENTRIES
RIGHT
OPTION
1
Enable Burg Module On System
2
Enable GEMC
-
F8ZCPIM
3
Enable Housing Tamper
4
Coded Alarms By Zone
5
ENABLE BURG POINT REPORT TAMPER ON (RF
-
XMIT
PNT/BSLC PNT TAMPER) ONLY IF ZONE ARMED
6
ENABLE RF RECEIVER OR BURG RF TRANSMITTER OR
SLC TAMPER TO SOUND BURG ALARM ONLY IF ANY
AREA ARMED
7
RESERVED
8
RESERVED