Freedom F-64 Programming Instructions
Page 33
WI1502A 9/06
ZONE OPTIONS - ZONES 49 TO 64 (ADDRESS 1285-1400)
ZONES 49
→
56
ZONES 57
→
64
ZONE FEATURES
ADDR Z49 Z50 Z51 Z52 Z53 Z54 Z55 Z56 ADDR Z57 Z58 Z59 Z60 Z61 Z62 Z63 Z64
1
2
3
4
5
6
7
8
1
2
3
4
5
6
7
8
Priority
1285
1349
Priority with Bypass
1286
1350
Auto-Bypass
1287
1351
Selective Bypass
1288
1352
Keyswitch Arming
1289
1353
Auto-Bypass Re-entry
1290
1354
Pre-Alarm Warning
1291
1355
Never Arm
1292
1356
24-Hour Zone
1293
1357
Alarm Output
1294
1358
Pulsed Alarm Output
1295
1359
PGM1 Output
1296
1360
PGM2 Output
1297
1361
Entry/Exit 1
1298
1362
Entry/Exit 2
1299
1363
Exit/Entry Follower
1300
1364
Auto Reset
1301
1365
Swinger Shutdown
1302
1366
Chime
1303
1367
Abort Delay
1304
1368
Power-up Delay
1305
1369
Day Zone Open
1306
1370
Day Zone Short
1307
1371
Alarm on Day Zone
1308
1372
Alarm Telco 1
1309
1373
Alarm Restore 1
1310
1374
Trouble Telco 1
1311
1375
Trouble Restore 1
1312
1376
Alarm Telco 3
1313
1377
Alarm Restore 3
1314
1378
Trouble Telco 3
1315
1379
Trouble Restore 3
1316
1380
No EOL Resistor
1317
1381
Trouble on Open
1318
1382
Trouble on Short
1319
1383
Zone Area 1
1320
1384
Zone Area 2
1321
1385
Interior (Stay) Bypass
1324
1388
Keypad Sounder on Alarm
1325
1389
Fire
(C)
1327
1391
Fire Alarm Verification
(C)
1328
1392
Zone ANDing Group 1
1330
1394
Zone ANDing Group 2
1331
1395
Zone ANDing Group 3
1332
1396
Zone ANDing Group 4
1333
1397
Sensor Watch
1334
1398
RESERVED
1335
1399
Chime 2
1336
1400
When the Easy Menu Driven Program Mode is used, these features are enabled by default.
Enabled when "Enable SIA CP-01 Features?" is activated (Answer "Yes" in the EZ Programming Menu).
Disabled when "Enable SIA CP-01 Features?" is activated (Answer "Yes" in the EZ Programming Menu). Disable Auto-Reset on non-fire zones for SIA CP-01 installations.
Zone Area 3
1322
1386
Zone Area 4
1323
1387
RESERVED
1337
1401
Perimeter Group Bypass
1338
1402
NOTES:
(A) 50ms Loop Response only available for zones 1-8. If Zone Doubling is enabled, Zones 9-16 will follow the loop response programming for Zones 1-8. For all
other Zones, loop response is determined by jumpers on the GEM-EZM8 and/or the configuration on the F-64PROG.
(B) 2-wire Smoke Detectors only available for zones 7 & 8, and
Fire
must also be selected.
(C) If Fire Alarm Verification is selected, then Fire must also be selected.
DEFAULTS:
The zone options indicated are automatically set after exiting the Easy Menu Driven Program Mode.
Priority, Selective Bypass, Alarm Output, Auto Reset, Swinger Shutdown
and
Zone Area 1
are enabled for the total number of zones entered in “
# OF ZONES IN AREA1 ENTER #
ZONES
”.
Alarm Telco 1
is enabled for the zone number(s) entered in “
REPORT ALL ZONES TO CENTRAL ZONES? Y/N
”.
Entry/Exit 1
and
Chime
are enabled for the zone number(s) entered in “
ENTRY/EXIT ZONES ENTER ZONE #
”.
Exit/Entry Follower
and
Interior Bypass
are enabled for the zone number(s) entered in “
INTERIOR ZONES ENTER ZONE #
”.
Pulse Alarm Output
is enabled for the zone number(s) entered in “
FIRE ZONES ENTER ZONE #
” or “
2-WIRE FIRE ZNS ENTER ZONE #
”.
Fire
is enabled for the zone number(s) entered in “
FIRE ZONES ENTER ZONE #
”.
2-Wire Smoke Detector is enabled for the zone number(s) entered in “
2-WIRE FIRE ZNS ENTER ZONE #
”.
DI
RECT A
D
DRESS PROGRA
M
MODE