L
NAPCO Security Systems
Freedom F-64 Programming Instructions
Page 21
WI1502A 9/06
SYSTEM OPTIONS (ADDRESS 1420-1424, 2051-2054)
*NOTE: Address 1423:
Default depends on Easy Menu Driven Program
Mode question :“
EZ ZONE DOUBLING? Y/N
”. If yes, then
[Default = 1]. If no, then [Default = blank (•)].
**NOTE:
To select “Line-Fault Test only when Armed”, you must also
select “Enable Line-Fault Test” at address 1423.
***NOTE:
If “Enable Global Ambush Code” in Address 1422 is selected, then
program the 2-digit “Global Ambush Code” in Address 2045. If
Address 2045 is left blank (•), then, the 2-digit “Global Ambush
Code” will be “99”.
****NOTE:
If this feature is not selected, the E15 Lug will, by default,
activate when the system is armed (all areas).
1420 System Options
1421
Default
Option
Default
Option
OFF
1
Opening Report Only after Alarm Report
OFF
1
Auto Bell Test on Arming
OFF
2
Closing Report Only on Conditional Close
OFF
2
Auto Reset after Burglary Output Timeout
OFF
3
Incl. Sel./Grp. Bypass in Cond. Close /Status
OFF
3
Suppress Bypass Reminder when Armed
OFF
4
Status Report
OFF
4
Enable Local Alarm on First Zone AND Trip
OFF
5
RESERVED
OFF
5
Access Control on PGM2 Output
OFF
6
Enable AutoArm if not closed at end of Window OFF
6
Maintained Keyswitch Arming
OFF
7
Enable Keypad Time/Date Display
OFF
7
Enable Manager's Mode
OFF
8
Disable Zone Fault Scrolling
OFF
8
Disable Keypad Instant Mode
System Options
1422 System Options
1423 System Options
Default
Option
Default*
Option
OFF
1
Interior Normally Bypassed
OFF*
1
Enable Zone Doubling (Zones 9-16)
OFF
2
Enable Global Ambush Code ***
OFF*
2
Wireless Trouble Activates Telco 1
OFF
3
Reset Day Zone with Arm/Disarm Only
OFF*
3
Wireless Trouble Activates Telco 3
OFF
4
Enable Residential Fire
OFF*
4
Enable Alarm Output on Telco Fail only when Armed
OFF
5
Disable Keypad Function Mode Download
OFF*
5
Line-Fault Test only when Armed**
OFF
6
Disable Callback Download
OFF*
6
Enable Line-Fault Test**
OFF
7
Chirp Output on Keyfob Arm/Disarm
OFF*
7
Inhibit System Trouble Audible at Keypad
OFF
8
Change Pulse Output to Temporal Output
§
OFF*
8
Select Alarm Output for Keyfob Chirp
§
This feature must be programmed in Fire Alarm applications.
Not for UL Installations.
2051 System Options
Default
Option
OFF
1
Enable Keypad Set Time/Date Message
OFF
2
Enable Cancel Report to Telco 3
OFF
3
Disable [ON/OFF] as Easy Exit
OFF
4
Enable GEM-PRINT Module
OFF
5
RESERVED
OFF
6
RESERVED
OFF
7
Disable System Trouble Audible Timeout
OFF
8
Enable "K Series" Style Keypads
††
†† NOTE:
For reference only and cannot be changed.
NOTE:
Option 7 required for UL Installations
1424
Default
Option
OFF
1
Automatic Interior Bypass/Easy Exit
OFF
2
Veri-phone Zones Trip PGM2 Output
OFF
3
Veri-phone Audio Priority Over Alarms
OFF
4
Resound on Wireless Smoke Low Battery
OFF
5
Don't Clear PGM2 Output with Disarm
OFF
6
Disable 2nd Call Ans. Machine Override
OFF
7
RESERVED
ON
8
Disable Code Required for EZ Bypass
System Options
2053
Default
Option
OFF
1
Exit Time Restart
OFF
2
Sound Alarm On Exit Error
OFF
3
Rpt Exit Err/Recent Close
OFF
4
Enable CP-01 Limits
OFF
5
Digital Dialer Rpt Enter /Exit Test Mode
OFF
6
Disable Call Waiting on 1st Attempt
OFF
7
Enable Keypad 1 Only Programming
OFF
8
Enable CP-01 Egress Tones Only
System Options
2054
Default
Option
OFF
1
Enable TCP/IP Communications
OFF
2
RESERVED
OFF
3
RESERVED
OFF
4
RESERVED
OFF
5
RESERVED
OFF
6
RESERVED
OFF
7
RESERVED
OFF
8
RESERVED
System Options
2052 E15 Lug / System Options
Default
Option
OFF
1
RESERVED
OFF
2
RESERVED
OFF
3
Lug E15 Area 1 Armed Away Only****
OFF
4
PGM on RF Transmitter Tamper
OFF
5
RESERVED
OFF
6
RESERVED
OFF
7
RESERVED
OFF
8
RESERVED
UL
UL
UL
UL
UL
UL
DI
RECT A
D
DRESS PROGRA
M
MODE