background image

operating ManUal & parts list for 791-7330

791-7330 

Rev. 08/04/10

tRoubleshootING

PRObLEM

ACTION

1. Unit will not lift load.

Purge air from hydraulic system by following procedure 
under SETUP.

2. Unit will not sustain load or feels “spongy”  
    under load.

Purge air from hydraulic system as above.

3. Unit will not lift to full height.

Purge air from hydraulic system as above.

4. Unit still does not operate.

Contact authorized service center. For a complete list of 
authorized hydraulic repair centers please visit www.
toolwarrantyrepair.com.

PREVENTATIVE MAINTENANCE

   

 

This is the safety alert symbol used for the PREVENTATIVE MAINTENANCE section of this manual to alert you to  

 

      potential personal injury hazards. Obey all instructions to avoid possible injury or death.

IMPORTANT:

The number one cause of jack failure in air/hydraulic jacks is dirt and moisture in the air motor and/or hydraulic sys-

tem. The shop air supply should be equipped with water and dirt filter traps that should be emptied or cleaned accord-

ing to a monthly maintenance schedule. An in line oil lubricator will extend the life of air/hydraulic jacks. Inoperable 

jacks caused by poorly equipped or maintained shop air systems are not eligible for warranty consideration. Contami-

nants can also enter the air/hydraulic system when the shop air line is disconnected from the jack air line and the line 

is dropped on the floor. Contaminants in the air couplers, once reconnected, will be driven into the system.

1. Always store the jack in a well protected area where it will not be exposed to inclement weather, corrosive vapors, abrasive dust,  

  or any other harmful elements. The jack must be cleaned of water, snow, sand or grit before using.

2. Lubricate moving parts with SAE 30 oil. Keep jack clean.

3. It should not be necessary to refill or top off the reservoir with hydraulic fluid unless there is an external leak. An external leak  

  requires immediate repair which  must be performed in a dirt-free environment by qualified hydraulic repair personnel who are  
  familiar with this equipment.

 

IMPORTANT: In order to prevent seal damage and jack failure, never use alcohol, hydraulic brake fluid or 

transmission oil in the jack.

4. Every jack owner is responsible for keeping the jack labels clean and readable. Use a mild soap solution to wash external surfaces  

  of the jack but not any moving hydraulic components.

5. Do not attempt to make any hydraulic repairs unless you are a qualified hydraulic repair person that is familiar with this 

  equipment. Repairs must be performed by an authorized service center.

WARRANty 

Please contact your local NAPA Auto Parts Store for details on warranty.

Summary of Contents for 791-7330

Page 1: ...derstand and follow all instructions before operating this device Inspect the jack before each use Do not use jack if damaged altered modified in poor condition leaking hydraulic fluid or unstable due...

Page 2: ...extension screw can be extended in order to save pump stroke to lift a load 2 Visual inspection should be made before each use of the jack checking for abnormal conditions such as damaged loose or mis...

Page 3: ...consideration Contami nants can also enter the air hydraulic system when the shop air line is disconnected from the jack air line and the line is dropped on the floor Contaminants in the air couplers...

Page 4: ...OPERATING MANUAL PARTS LIST FOR 791 7330 791 7330 4 Rev 08 04 10...

Page 5: ...5 46 SPRING WASHER 5 47 SCREW 5 48 FRAME ASSY 1 49 HEX SOCKET HEAD BOLT 2 50 RS33000 COVER PLATE 1 51 RS6620A41 RELEASE KNOB INCLUDING 52 1 52 LOCK PIN 1 53 RELEASE LINK I 1 54 SCREW 2 55 RELEASE LIN...

Page 6: ...DA USO NO USE EL GATO SI STE EST DA ADO MODIFICADO ALTERADO EN POBRES CONDICIONES SI HAYA FUGAS DE ACEITE HIDR ULICO O SI EST INESTABLE DEBIDO A FERRETER A O PARTES FLOJAS O FALTANTES HAGA LAS CORRECI...

Page 7: ...extenderse con el fin de ahorrar recorridos de la bomba para el levantamiento de la carga 2 Se debe realizar una inspecci n visual antes de cada uso del gato revisando por condiciones anormales tales...

Page 8: ...al mes con una grasa de uso general 3 No ser necesario rellenar ni completar el rellenado del tanque con l quido hidr ulico al menos que haya una fuga externa Una fuga externa requerir una reparaci n...

Page 9: ...R LE CRIC S IL EST ENDOMMAGE ALTERE MODIFIE OU EN MAUVAIS ETAT SI LE LIQUIDE HYDRAULIQUE FUIT OU SI LE CRIC EST INSTABLE EN RAISON DE PIECES MANQUANTES OU LACHES APPORTER LES CORRECTIONS OU LES REPARA...

Page 10: ...lever une charge 2 Le cric devrait faire l objet d une inspection visuelle avant chaque utilisation tre l aff t des conditions anormales telles que les pi ces endommag es l ches ou manquantes Si un cr...

Page 11: ...par la garantie Des contaminants peuvent galement p n trer dans le syst me d alimentation en air hydraulique lorsque les conduites de l atelier et du cric sont d connect es et pos es au sol Les contam...