Special Operations
4.6.3
R
ECTANGULAR
RASTER
The following drawing describes the operation in case of rectangular raster
(Options bit 12 is zero). The drawing also implies Options bit 0 is zero; if the bit
is one, axes X and Y change their roles.
Figure 5: Rectangular Raster
Dwell
Real (4)
Dwell in milliseconds in a trigger point.
The parameter is only used in Step-repeat
operation; in normal operation, the
parameter is ignored.
Pulse Width
Real (4)
Width of trigger pulse in milliseconds.
Pulse Count
Int32 (4)
The number of trigger pulses on one vector.
The parameter is meaningful only if Options
bit 12 is zero; otherwise, the parameter is
ignored, and individual pulse count is defined
with each vector.
Vector Count Int32 (4)
The number of vectors.
The parameter is meaningful only if Options
bit 12 is zero; otherwise, the parameter is
ignored.
Table 6: Raster Data Commands Parameters
Parameter
Format
Comments