XCDX458000-00 rev A
34
4
XCDX C
OMMUNICATIONS
P
ROTOCOL
4.1
COM S
ETTINGS
XCDX Commander automatically configures the selected COM channel.
If the customer creates his own program to communicate with XCDX, the
COM channel should be configured as follows:
• Baud Rate: 115200
• Number of Data Bits: 8
• Parity: None
• Number of Stop bits: 1
• Flow Control: None
4.2
D
ESTINATION
A
DDRESS
Each command sent to XCDX has a field of destination address. Destination
address defines which controller processes the command. The following
destination addresses are recognized:
• 1 - XCD 1 (X)
• 2 - XCD 2 (Y)
• 3 - XCD 3 (Z)
• 4 - XCD 4 (T)
• 128 (0x80) - MCU
Commands sent to channels 1/2/3 follow the standard XCD protocol; see XCD
User Manual for full specification. The total length of the commands should not
exceed 50 bytes.
Commands sent to channel 128 (0x80) are extended commands executed in
MCU; see XCDX Commands for details. The total length of the commands is
up to 80 bytes.