![Nanomotion XCDX User Manual Download Page 17](http://html.mh-extra.com/html/nanomotion/xcdx/xcdx_user-manual_705065017.webp)
XCDX458000-00 rev A
17
Specifications
2.1.6
I
SOLATED
SIGNALS
The XCDX Box provides internally isolated inputs and ouputs.
• Limits
• INS - isolated IO inputs
• PLD_INS_IN
• PLD_INS_OUT
Each of the following images shows the isolated circuit.
B16
INS_OUT
5
Do not use
B17
INS_IN2
Do not use
B18
INS_IN4
Do not use
B19
INS_IO_
COM
Do not use
B20
AI 1
input
T-Axis Analog Input 1
+/-10V
B21
GND
GND
B22
AO 2
output
X-Axis AO 1
0V-10V
B23
AI 3
input
Z-Axis Analog Input 1
+/-10V
B24
GND
GND
B25
AO 4
output
Y-Axis AO 1
0V-10V
B26
AI 5
input
Y-Axis Analog Input 1
+/-10V
B27
GND
GND
B28
AO 6
output
Z-Axis AO 1
0V-10V
B29
AI 7
input
X-Axis Analog Input 1
+/-10V
B30
GND
GND
B31
AO 8
output
T-Axis AO 1
0V-10V
B32
INS_IO_
COM
Do not use
B33
INS_OUT
2
Do not use
B34
INS_OUT
4
Do not use
B35
INS_IN1
Do not use
B36
INS_IN3
Do not use
B37
INS_IN5
Do not use
Table 5: J5B - Analog IO, Connector 1
Pin
Name
Direction
Description
Voltage