AB2 Driver Box User Manual
Connections and I/O Settings
13
2.6 Fault
Output
The Fault Output follows open collector logic. When activated by shorting to
ground it disables the motors under the following conditions:
•
Over-current (8A)
•
Over voltage
•
The motor is not connected and the “Motor Connected”
signal (section
2.4) is floating
•
The AB2 is disabled or the Emergency Stop input is
activated
•
One of the Limit Switches is activated
NOTE:
The Fault output is capable of sinking a maximum of 20 mA, and is not
protected from over current.
2.7 Before
Operating
the
Motor
Before operating the AB2, verify the following:
•
Jumper JP1 is set to the required mode of operation (see
section
2.5.1)
•
Mechanical screws lock all connectors
•
The external power supply is capable of supplying the
required power consumption of the AB2 (see Table 3)
•
There is no command when switching the power to “ON”
•
All motors are correctly mounted and preloaded.
ATTENTION:
1. The command should be limited according to the
envelope of performance of the motor. Refer to
the Motor User Manual.
2. Driver should be grounded to infrastructure
earth before operating.