![Nanomotion AB2 User Manual Download Page 20](http://html.mh-extra.com/html/nanomotion/ab2/ab2_user-manual_705062020.webp)
Connections and I/O Settings
Opto-isolated Inputs
Nanomotion Ltd.
12
2.5.1 Voltage Source Configuration.
The opto-isolated input signals (2.2.1) are activated as short-to-ground. The
voltage for the opto-isolated circuit (see Figure 8) is provided by either the
in5V supply (default state) or an external voltage supply via pin 13 on the
I/O Port connector. The input to be activated should be shorted to external
voltage supply ground.
Configure jumper JP 1 on the AB2 card according to the voltage source:
•
Pin 1 shorted to Pin 2, for an in5V source (default
factory setting)
•
Pin 2 shorted to Pin 3, for an external voltage source
Connection for
Internal
source
T1
JP1
1
T1
JP1
1
Connection for
External
source
Figure 8: Jumper 3 Configuration
ATTENTION:
Do not short Pin 1 to Pin 3 on JP3. Doing so shorts the
external power supply to the +5V supply! The input circuit is
limited to sink up to 10 mA but not less than 3 mA.