14
1. Connect the device to a
power supply. When the
device is powered (24
V/AC-DC) it reverts to the
stand-by mode and blue
LEDs
will
illuminate
“ON/OFF”
button and side
segment
2. By pressing the
“ON/OFF”
button once, the fans
switch on at minimum
speed, the side segment
blue backlight turns on.
Pressing a second time,
the device turns OFF
3. Fan
Max
Speed
is
automatically regulated by
lift
electric
connection,
and type of setting on Dip
Switch selector. Below are
listed
all the
possible
combinations:
ON
Use the word
“ON”
placed on Dip-Switch as
directional reference.
Switch 4/1
Switch 3/2
Position 4 (closed)
device will turn on at
fan max. speed for all
the
time
when
lift
RELAY will be open,
when lift RELAY close,
device will turn off.
Position
3
(extra
time)
with this switch
OFF, device will work
with extra time settings
(approximately
120
sec.) after lift RELAY
close.
Position 1 (open)
fan
speed max speed will
be managed by lift
RELAY closing. When
lift RELAY opens, fan
speed will be turned to
min. speed.
Position 2 (normal
time)
with this switch
ON, device will work
with
default
time
settings, as indicated in
the left column.