Modifying the breathing 

monitor

Do not open or modify the monitor. Otherwise, the manufacturer 

cannot guarantee the correct functionality and usability of the 

monitor and assumes no responsibility.

Mechanical damage 

to the device

Do not use the monitor in case of mechanical damage, such as 

breakage of a large part of the device’s plastic cover - this could 

cause excessive release of light or sound, which could harm your 

child. If the indicator symbols are no longer legible, for example 

due to careless or incorrect cleaning, only use the device if you 

can correctly distinguish the light indications of the symbols , 

or ensure that the symbols are marked in an alternative way 

(sticker or special marker pen). Otherwise, send the device for 

service.

Wireless technology 

in range

Please use wireless communication devices, such as wireless 

home networks, mobile phones, cordless phones, and their base 

stations, portable stations, which may affect the proper operation 

of the monitor, at a distance of at least 1 m from any part of the 

monitor.

Amateur radio 

equipment in range

Amateur radio transmitters and their antennas should be at 

least 10 m away. However, the manufacturer cannot guarantee 

the proper functioning of the monitor during radio operation 

due to the various types of equipment, transmission powers and 

antenna systems. 

Baby supervision -

help within reach

Please note that the device can only alert you, but it does not of 

itself prevent the risk of respiratory arrest! If the child has a  

health problem, it is up to you or the doctor to help it. Likewise, 

do not move too far away from your child so you cannot hear 

and be able to respond to an alarm. Do not use the monitor 

in an environment where you may not hear or see the alarm (an 

environment that is too noisy or too bright). Supervision must 

be carried out only by sighted and hearing persons who are able 

to correctly distinguish the alarm and help the child.

Guarantee

The manufacturer is responsible for the functionality of the 

BM-03 product if it is installed and used according to this ma-

nual and its recommendations, otherwise it does not bear any 

responsibility. The manufacturer is not responsible for the 

proper functioning of the product if it has suffered mechanical 

or other damage or if the product’s life span has been excee-

ded. The manufacturer is not responsible for battery defects.

A used or borrowed  

breathing monitor

The manufacturer strongly discourages buying this product 

used or getting it from a hire company. If it is handled 

incorrectly, the sensing device’s sensitivity may be reduced 

leading to, among other things, an increase in false alarms. 

In these cases, the manufacturer is not responsible for the 

product’s functionality.

Summary of Contents for BM-03

Page 1: ...BM 03 Baby breathing monitor Certified medical device...

Page 2: ...aning 8 Alarm states 9 Operator warning 10 Important warning 11 Problems and how to solve them 12 Technical specifications 13 Definitions and symbols 14 EMC of a medical device 14 1 EMISSIONS limits b...

Page 3: ...ants for example due to sudden infant death syndrome SIDS or due to other causes suffocation an illness etc Due to the nature and purpose of use no side effects and other contraindications are known T...

Page 4: ...ONITOR Based on signals from the sensor pad located under the baby the device monitors the regularity of breathing and signals respiratory arrest Inhalation and exhalation are indicated by a green fla...

Page 5: ...bsence or presence Functionality test results A All indicators flash and short beep all checks were successful and the device is fully functional B Flashing lights and repeated warning beeps error dia...

Page 6: ...hich is mainly used to check on the baby at night Activation and deactivation of the light function The lamp function is deactivated by default To activate it simultaneously press the mechanical butto...

Page 7: ...t day and night or darkness Thanks to this the light diodes light up at night with a lower intensity than during the day to ensure parents or other caregivers have a good night s rest Day and Night mo...

Page 8: ...onnecting the connecting cable to the control unit Neither the sensor pad nor the control unit need to be specially cleaned or disinfected after unpacking Before using the monitor make sure that all p...

Page 9: ...dhesive tape to place it on the side of furniture or another solid surface cot clip a stand for the control unit it can be placed for example on the bedside table next to the bed Fig 10 Holder and Vel...

Page 10: ...eliminated in order to ensure the device works reliably and the baby is safe Disturbance can be caused by intense airflow fans air conditioning walking near the bed mechanical vibration from househol...

Page 11: ...nd the mechanical button will flash 3 times It is best to buy a set of 2 pads The second pad can be used in multiple places in the baby s first months of life for example in another bed at its grandpa...

Page 12: ...the mattress 180 in the cot once in a while or turn it upside down or let it air etc Only use a slightly damp cloth for cleaning Avoid wet wipes or other materials that may have loose fibres that can...

Page 13: ...n with the pad evaluated in active mode Moderate Orange colour flashes in a circle around the mechanical button 5 Hz 100 ms light 100 ms pause Technical alarm high intensity intermittent tone 100 ms t...

Page 14: ...use Lasts until the high temperature is no longer detected No acoustic signal Indication that the sensor pad is disconnected in standby mode evaluated in standby mode 3x red flashes in a circle around...

Page 15: ...nd must be placed at least 0 5 meters away from the child s head to prevent possible damage to its hearing Correct placement of the cot The device uses a very sensitive sensor to sense breathing Its o...

Page 16: ...eration due to the various types of equipment transmission powers and antenna systems Baby supervision help within reach Please note that the device can only alert you but it does not of itself preven...

Page 17: ...ance in the surroundings that need to be removed Follow section 4 After switching on the device indicates empty batteries Make sure you have not used rechargeable batteries they have a lower voltage a...

Page 18: ...tion IP31 Life span of the sensor pad 2 years from putting into service Service life of the control unit 10 years Service life of the device 10 years under the condition of replacing the sensor pad af...

Page 19: ...1 EMISSIONS LIMITS BY ENVIRONMENT Phenomenon Professional medical facilities a Home health care a RF emissions propagated by conduction and radiation CISPR 11 CISPR 11 c d Harmonic distortion see IEC...

Page 20: ...ces and ME systems with magnetically sensitive components or circuits e During the test the ME instrument or ME system may be supplied with any nominal input voltage but at the same frequency as the t...

Page 21: ...1990 GSM 1800 1900 CDMA 1900 DECT LTE Band 1 3 4 25 UMTS Pulse modulationb 217 Hz 2 0 3 28 1845 1970 2450 2400 to 2570 Bluetooth WLAN 802 11 b g n RFID 2450 LTE Band 7 Pulse modulationb 217 Hz 2 0 3 2...

Page 22: ...A new life begins MXA51302...

Reviews: