N & W Global Vending – TECHNI CAL MANUAL
This document w as produced by MARK AC for the exclusive use of the technical personnel in the after- sales service.
All rights reserved. No part of this document may be divulged to a third party or reproduced partially or entirely w ithout the prior permission of N & W GLOBAL
VENDI NG
“KORI NTO FB”
23/ 08/ 06
Page 25 / 38
Boiler temperature ° C
Value in ohm
Allow ed tolerance
0 35875
+ / -7
ohm
25
12000
+ / - 4 ohm
50 2900
,,
85 1475
,,
90 1260
,,
100 963
,,
POMPA
Description for disassembling
First, remove the front protective
casing (
1
) and to accomplish this
remove the side panels that close the
internal frame and undo the front
fastening screws (
2
), then slide out
the panel.
Undo the two screws (
3
) that partly
secure the casing.
Take out the casing.
Remove the boiler, disconnecting both
hydraulic connections and wiring
connections.
Before removing the boiler wait until it
has cooled down.
1
3
2
4