A3LA-R User Guide Version A
Document Number: 451-93156-001A
79 of 158
20-255 (in 10-ms unit).
Default is 25.
<mode> is used to indicate the mode of operation and can take on the following
values:
0
unacknowledged mode of operation
1
acknowledged mode of operation (default)
NOTE:
For the proper operation of the IRLP procedures, t2 should be less than t1 and
2*t4 should be less than t1.
Read Command:
+WIRLP?
Query the actual IRLP parameters resulting from the negotiation (XID exchange) at
the start of the most recent data call. Note that these may differ from the desired
parameters set using “+WIRLP=…”; from power-up they are set to hardcoded defaults,
and will only change as the result of the negotiation. The response is in the form:
+WIRLP: <ver>, <k1>, <k2>, <t1>, <n2>, <t2>, <r1>, <r2>, <t4>, <mode>
Test Command:
+WIRLP=?
List the supported IRLP parameter settings. The response is in the form:
+WIRLP: (supported <ver>s), (supported <k1>s), (supported <k2>s), (supported
<t1>s),
(supported <n2>s), (supported <t2>s), (supported <r1>s), (supported <r2s),
(supported <t4>s), (supported <mode>s)
B.81 +WFRNG
–
F
ORCE
IRLP
R
ENEGOTIATION
Set Command:
+WFRNG=<frng>
Set forced renegotiation of IRLP parameters.
<frng> can take the following values:
0
Do not renegotiate (default)
1
Renegotiate
2
Disconnect
Read Command:
+WFRNG?