background image

 

Redwing105

AirLink CDMA Modem C3111

Revision: 7/06

C o p y r i g h t   ©   2 0 0 4 - 2 0 0 6

C a m p b e l l   S c i e n t i f i c ,   I n c .

Summary of Contents for C311

Page 1: ...Redwing105 AirLink CDMA Modem C3111 Revision 7 06 C o p y r i g h t 2 0 0 4 2 0 0 6 C a m p b e l l S c i e n t i f i c I n c ...

Page 2: ... all other warranties expressed or implied including warranties of merchantability or fitness for a particular purpose CAMPBELL SCIENTIFIC INC is not liable for special indirect incidental or consequential damages Products may not be returned without prior authorization The following contact information is for US and International customers residing in countries served by Campbell Scientific Inc d...

Page 3: ... 1 2 Specifications 1 2 1 Base Station Requirements 1 2 2 Datalogger Site Equipment 1 2 3 Power Considerations 2 3 Configuration 2 3 1 Establish Cellular Service 2 3 2 Program the Modem 2 3 3 Setup LoggerNet 3 Appendix A Configuring Modem with a Terminal Emulator A 1 A 1 HyperTerminal Setup A 1 A 2 Programming the Redwing s Phone Number A 2 A 3 Programming the Redwing for Use with a Datalogger A 3...

Page 4: ...This is a blank page ...

Page 5: ...7 CR5000 or CR2XX SC105 or SC932A Interface connects the modem to the CR510 CR10 X or CR7 dataloggers CS I O port 14392 Null Modem Cable connects the modem to the CR23X CR2XX CR1000 or CR5000 RS 232 port 14394 Redwing Mounting Kit includes mounting hardware for securing the modem to below referenced environmental enclosure and a 9 pin male to 9 pin female cable Antenna the following antennas are a...

Page 6: ...ike to open an account for a new voice phone Request a voice plan and ask that voice mail NOT be activated The Redwing may show up on Alltel s network as a MultiTech device this is okay The provider will provide you with the following 1 MDN Mobile Directory Number This is the number you dial 2 MIN Mobile Identification Number This number identifies the Redwing on the cellular network This may be t...

Page 7: ...t page select your installed modem on the Tapi Line 5 On the TapiRemote un check Use Tapi Dialing Properties 6 Enter the phone number of the CDMA phone 7 Apply the changes and test If you have a black SC12 cable that is not Rev 1 or newer it is a CS I O cable only and will not work for RS 232 Connect the black SC12 cable between the datalogger and the SC932A Use a 9 pin serial cable or a blue ribb...

Page 8: ...Redwing105 AirLink CDMA Modem 4 This is a blank page ...

Page 9: ...tems needed Computer with a COM port 9 pin cable to connect between the computer and the Redwing A terminal program on the computer HyperTerminal 12 volt DC applied to the Redwing Antenna on the Redwing for over the air updates CDMA account A 1 HyperTerminal Setup Under Connect using select the COM port you will be using Set COM Properties to Bits per second baud 115200 Data bits 8 Parity None Sto...

Page 10: ...N MDN Example AT WMDN 4352551212 OK Enter the MDN here The MDN is the number used to dial this device 3 AT WIMI 31000 MIN Example AT WIMI 310004352551234 OK Enter the MIN here The 31000 must precede the MIN The MIN is the number used to identify this device on the cellular provider s network This number may be the same as the MDN OK Commits the changes done during the service programming session 4...

Page 11: ...auto answer in data mode 7 AT IFC 0 0 OK Disables local flow control Sets the Redwings RS232 baud rate and saves settings Use the following to determine baud rate CR1000 CR5000 115200 CR23X 38400 8 AT IPR baud rate W Example AT IPR 9600 W OK CR10 X CR510 CR200 CR7 9600 In the above strings all 0 zero Remove the power from the modem and power it up again It should be ready to use at the baud rate s...

Page 12: ...Appendix A Configuring Modem with a Terminal Emulator A 4 This is a blank page ...

Page 13: ...This is a blank page ...

Page 14: ... campbellsci com br suporte campbellsci com br Campbell Scientific Canada Corp CSC 11564 149th Street NW Edmonton Alberta T5M 1W7 CANADA www campbellsci ca dataloggers campbellsci ca Campbell Scientific Ltd CSL Campbell Park 80 Hathern Road Shepshed Loughborough LE12 9GX UNITED KINGDOM www campbellsci co uk sales campbellsci co uk Campbell Scientific Ltd France Miniparc du Verger Bat H 1 rue de Te...

Reviews: