A3LA-R-MIL-MOD User Guide Version B
Document Number: 451-93156-001A
110 of 159
+ANTST:<ant_status>
where:
<ant_status>:
0
Built-in antenna is stowed
1
Built-in antenna is deployed, or an external antenna (via docking cradle) is
connected, and the built-in antenna is disconnected so its
stowed/deployed status is irrelevant
The +ANTST:<ant status> message will be sent whenever internal polling indicates
that the antenna status has changed, or on polling after +WANTST has been received
regardless of whether the state has changed or not. An initial state of ‘stowed’ can be
assumed, but +ANTST:<ant status> will be sent shortly after initialization with the
actual status in any case. Internal polling will measure the deployment and docking
detector states before any overall state change is announced.
Note that internal polling occurs on each main receiver receive activity, i.e. once per
90ms during a call, at least once every 4.3 seconds while monitoring a Ring signal, and
as infrequently as once every 2 minutes when performing Ring searches with no signal
present.
B.114 +PCDA
–
P
ENDING CALL DROP ALERT
Exec Command: none
Unsolicited Announcement: +PCDA:<alert_status>
where:
<alert_status>:
0
Pending call drop alert is inactive
1
Pending call drop alert is active
The +PCDA message will be sent whenever the pending call drop alert status changes.
B.115 +DPLCI
–
DPL
C
ALL
I
NDICATION
Exec Command: none
Unsolicited Announcement: