9602-LP User Guide Version A
Document Number: 451-92750-001A
24 of 61
approach described previously. Once valid motion is determined, the 9602-LP switches to
“Callable (Moving Yes | Still No)” and “in motion” mode.
The setup parameters for “Callable (Moving Yes | Still No)” and
In Motion or Motion
are
similar to the “Callable (Yes)” option, except the motion sensor is active. The 9602-LP uses
Minutes of Motion Before Waking
and
Sensitivity
to determine if valid motion is observed by
applying the same approach described above. If valid motion is not detected before the
Minutes of Calm Before Sleeping
expires, the 9602-LP switches back to “Not in Motion or
Low Power” mode.
Figure 12: Normal Tracking “Callable (Moving Yes | Still No)” Option
3.1.2.2
E
MERGENCY AND
T
EST
T
RACKING
M
ODES
Emergency Tracking can be triggered by the Emergency button (see
) or by input
pin S0. Test Tracking can be triggered by input pin S1. Emergency Tracking and Test
Tracking operate similarly to Normal Tracking in that they have individually configurable
reporting parameters. While in Emergency Tracking, the 9602-LP does not respond to the
+++ escape sequence, and at least one “report send attempt" must be completed before
transitioning back to Normal Tracking. The Emergency GPS reports have a special data bit
activated to alert the recipient of the message type. The 9602-LP allows GPS reports to be
saved on its nonvolatile memory when an Iridium satellite is not available.