25
ENGLISH
8
. CONNECTION OF AIR HOSE AND AIR SUPPLY
CAUTION
Securely connect the air hose to the brushless motor and air line kit to avoid
accidental disconnection and injury to the operator during use.
CAUTION
Ensure that the pressure at the Spindle ATC Inlet is 0.6MPa (87psi).
As illustrated in the picture, measure the pressure as close to the Spindle as
possible.
(1) Connect the provided
ȭ
6mm air hose with
¿
lter and 3-way valve to Air Inlet Joint
shown in Fig. 3.
(2) Supply clean air from air compressor through air
¿
lter or air dryer to the 3-way valve
at the air pressure : 0.6MPa (87psi).
Filter
3 - Way Valve
ȭ
6mm Hose
ȭ
6mm Hose
Dry Air
Air Release
Air Supply
(Supply Side)
Fig. 3
Air Supply
(
Supply Side
)
Pressure Gauge
T - Type Joint
ȭ
6 One - Touch Joint
Fig. 4