14
Pin5
(AUTO+)
Pin13
(AUTO-)
3 Pin
11
4 Pin
12
Pin6
(PWON+)
Pin14
(PWON-)
! "
# $ % &
& ' '( & &
' '( & & )
)
!
'*+,#-(
CN1
Short circuit pin
.
(3)SAFE A/B PIN No. 3, 4, 11, 12)
・The Safety Relay will be ON or OFF depending on the state of the Emergency Stop Signal PINs 1
and 9.
・When there is continuity between PIN 3(SAFE-1A) and PIN 11(SAFE-1B) or between PIN 4 (SAFE-
2A) and PIN 12 (SAFE-2B) the motor is off. If there is no continuity between these pairs of pins
then the system is operating normally.
・If the Emergency Stop Signal is OFF (Open) the Safety Relay will be OFF(Open) and the motor
power will be interrupted and the motor will stop.
・If the
a
contacts of the Safety Relay are welded together by an over load or short circuit the
b contacts
,
separation is maintained with more than 0.5mm spacing by the relay
,
s recoil
mechanism
①CN1 Connector Rating-Relay Contact Rating
Current Rating
3A AC・DC
Voltage Rating
250VAC・DC
②Relay Contact Rating (At resistance load COSφ=1)
・Max. Current
6A
・Load Rating
AC250V・DC30V 6A
・Max. Voltage
AC250V DC125V
・Current Rating
6A
(4)AUTO (AUTO MODE Signal ) (CN1: Pin5, Pin13)
When Control Switch is set to AUTO MODE, Pins 5 and 13 are
ON(Closed).
When Control Switch is set to MANUAL MODE, Pins 5 and 13 are OFF
(Opened).
/0
(The max. rating of transistor is V
CEO
=50V, I
C
=50mA, P
C
=100mW. Please
use at less than the maximum rating)
(5)PWON (Control Unit Power Source Detector) (CN1: Pin6, Pin14)
When the control unit's power source is connected and the Power
Switch is ON, Output Transistor is ON (Closed).
/0
(The max. rating of transistor is V
CEO
=50V, Ic=50mA,
Pc=100mW. Please use at less than the maximum rating)
(6)External Input/Output Connector CN1 Pin Arrangement
/.0