21
〜
▲ Entering Parameter Setting Mode
・While pushing and holding the Reset Switch turn the Power Switch On. Hold the Reset Switch down
for 3 seconds, the buzzer will 'beep' 3 times, release the Reset button and Parameter Setting Mode
will start. The Start LED flashes to indicate Parameter Setting Mode is active.
・Motor Start/Stop commands and the Start Switch on the Control Panel are disabled during Parameter
Setting Mode.
・Cycling the Power Switch will exit Parameter Setting Mode and return the system to normal operating
mode.
・After entering Parameter Setting Mode the parameters to be set can be selected by turning the
potentiometer.
〜
and
Error Output Mode
AUTO Mode Motor Speed Control
Fixed Motor Speed for Motor
Maximum Motor Speed for Motor
External Motor Start Signal Control Mode
Air Input monitoring override
Confirm settings of parameters P1-P6
Not Used
Once a parameters default setting has been changed the setting will be maintained even if
power is disconnected. Please set the Error Output Mode, AUTO Mode Motor Speed
Control, Fixed Motor Speed for Motor, and Maximum Motor Speed for Motor.
!
CAUTION
⑥Air Input monitoring override
The system can be configured to operate without cooling air, maximum speed is 25,000min
-1
.