. OPERATION
Bowl
Drain Valve
Upper Oil Limit
Draining
Stop draining
Drain Outlet Port
Fig. 2
5 - 1 Air Filter (Fig. 2)
5 - 3 Regulator
‚0
‚4
‚2
1‚0
MPa
‚8
‚6
Pressure Gauge
Regulator Knob
Increased
Decreased
Lock
Release
Fig. 3
Lever
ON (Open)
OFF (Close)
Fig. 4
The water, dirt and debris are separated from the
compressed air.
The separated debris is collected in the Bowl.
5 - 2 Draining (Fig. 2)
Opening and closing the drain valve.
Counter clockwise direction : Draining
Clockwise direction
: Stop draining
<
To divert the drain to another location
>
Connect a inside diameter
ȭ
6mm hose (Not included /
provided by the end-user.) to the Drain Output Port and
divert to another location.
<
Lock and Release of the Regulator Knob
>
Regulator Knob is equipped with Lock mechanism.
Lock
: Push the Regulator Knob IN to the Lock position.
Release : Pull the Regulator Knob OUT to unlock.
<
Adjusting Air Pressure
>
Turn the Regulator Knob while watching pressure gauge
increase or decrease.
Clockwise direction
: Air pressure is increased.
Counter-clockwise direction : Air pressure is decreased.
5 - 4 ON - OFF Valve
Turn the ON / OFF Lever located on the valve 90-Degrees
to turn the air output ON (OPEN) or OFF (CLOSE).