10
CAUTION
①
Use of dry air
Using compressed air containing excessive moisture could result in malfunction or failure
of the motor and spindle. If excessive moisture or condensation is found in Air Filter Bowl, it
will be necisary to install a larger Air Filter or dryer on the primary side of the Air Line Kit to
prevent and remove excessive moisture.
②
Draining
Be sure to drain moisture and condensation from Air Filter Bowl regularly to avoid moisture
being carried to Motor and Spindle.
③
Installation Location
Place this Air Line Kit on a flat and level surface.
If mounting on a wall, check if the wall is flat, and securely mount the Air Line Kit in a
horizontal direction.
④
Handling
When removing the bowl for cleaning, carefully remove the bowl and do not damage to the
bowl.
CAUTIONS FOR STORAGE, INSTALLATION and OPERATION
①
Do not use the Air Line Kit where corrosive gasses, chemicals, seawater, water, oils or steam
exist.
②
Do not place in direct sunlight.
③
Do not use where the Air Line Kit is subject to vibration or repetitive shock.
④
Do not use where a heat source or radiated heat exist.
⑤
To conform to "STORAGE, INSTALLATION and OPERATION" (Refer to " 3. SPECIFICATIONS ".)
①
This Air Line Kit is designed to supply clean and dry cooling and purging air to CONTROLLER and Motor /
Spindle.
②
The Air Filter traps small amounts of water and impure substances from the input air supply. This Air Line Kit is
not intended to be used or replace an Air Dryer.
③
Air Pressure Regulator supplies steady airflow at a regulated air pressure.
④
The Air Line Kit can be wall mounted.
2
. FEATURES
Summary of Contents for AL-C1204
Page 8: ...2013 01 20 005 Ⓢ ...