Page 8 of 15 Copyright © NAGRAVISION S.A. 2011 August 19, 2011
Rear panel description
USB connector.
This is used for setting up the recorder via PC or for downloading the recorded files. No power from the
Nagra-EMP is required to setup or download the recorder files.
Hirose DC connector.
Beware that the maximum power draining reaches 3.5 W (recorder included) and that the voltage range
goes from minimum 9 V up to maximum 13 V. When using the external power, the internal batteries are
automatically disconnected.
Line output XLR’s.
The line output level can be preset inside the Nagra-EMP (jumpers S4,
S5, S6 for CH1and S7, S8, S9 for CH2). 3 levels are available. To set
the jumpers, switch the unit off and remove the bottom panel.
S4, S9 = 4.40 V, 15 dBu for FS
S5, S8 = 1.55 V, 6 dBu for FS
S6, S7 = 0.775 V, 0 dBu for FS