Accessories (Options)
NDRA91-92
Manual
Page 84
NADO
Check the signal strength of the
NDRA91
:
Laser beam on traffic signs = strong signal, target LED is green, signal
strength > 1500
Laser beam not on traffic signs = weak signal, target LED is red, signal
strength < 1000
Vertical and horizontal adjustment of the rear sight on the edge of the
target by using the 2 screws (red dot adjust to edge).
Check the results:
Red dot and laser beam on the target results in strong signal.
Red dot and laser beam near the target, signal strength is lower than
before.
10.5
Adapter plate
NDRA911911060-AP
An adapter plate can be delivered for attaching the
NDRA91
. This adapter
plate is bolted to the case back of the
NDRA91
, and offers different options for
adapting the device, e.g. a tripod thread ¼-20 UNC.
When replacing the
NDRA500
C by an
NDRA91
, the existing fixing holes can
be
further used.
For parameter setting an optional programming cable is available to link the
NDRA50
with a PC (COM port, RS-232). The use of the PC software
NDRA
Tool
is recommended.