NDRA91-92
Manual
Description of commands
NADO
Page 63
7.4
Operation Mode
DM – Single distance measurement
The
NDRA91
carries out exactly one measurement and waits for new
commands afterwards.
The duration of a measurement depends on the number of the set
measurement values SA and the set measurement frequency MF.
The time between sending the command DM and the output of the
measurement value is 500 μs maximum.
DT – Continuous distance measurement
Continuous distance measurement is carried out and can be stopped with the
suitable command (RS-232/RS-422: Escape = 0x1B).
The output rate of the measurement depends on the number of the set
measurement values SA and the set measurement frequency MF.
DF – Measure single distance with external triggering
The operating mode DF must be set for the
NDRA91
. When an external trigger
signal is received, the device carries out exactly one measurement and waits
afterwards for the next trigger event in the operating mode DF.
The operating mode must be terminated with the corresponding command
(RS-232/RS-422: Escape = 0x1B9).
The trigger event has to be applied to the external trigger connection (see
chapter 5.5).
The intervals between the single measurements depend on the set
measurement values SA, the set measurement frequency MF and the set
trigger delay TD.
VM – Single speed measurement
The
NDRA91
carries out 25 single speed measurements from which the speed
is calculated.