background image

 

7

Machine Maintenance 

 

It is highly recommended to follow these maintenance procedures: 

1.  After using the machine, before storing it, remove all the water from the 2 tanks. Put 

some clean water inside the solution tank and drain it completely by turning the pump on 

and spraying water through the foam brush accessory. This operation is useful to clean 

the water system of the machine, including the pump, the couplings, and the nozzle. 

2.  After each use, empty the compressed air tank, spraying air only, until the tank is 

completely empty.  

3.  Periodically clean (at least every 2 months) the water filter, removing it from the machine 

and rinsing it under warm water. 

4.  Clean the vacuum motor filter. 

5.  Every 6-8 months, the machine may need to be delimed. This process is done by running 

a deliming chemical through the pumping system. 

6.  Periodically bring the machine to a service center to check the machine and all of its 

functions. Wearing parts like carbon brushes, bearings, etc. which must be replaced in 

time to avoid damage to the other components of the machine can not be then covered 

by warranty. 

7.  Every 2-3 months, drain the air tank by the valve located at the bottom of the air tank. 

Condensation forms in the air tank during normal usage. To do this, unscrew the circular 

cover located below the machine, locked with 2 screws. Unscrew the air tank drain cap, 

without removing it completely. Screw the cap and the circular cover on again. 

 

ATTENTION: 

This operation must be done with the compressor completely empty and with 

the machine switched off. 

 

Compressor maintenance 

 

The compressor used in the machine is oil less and therefore does not require frequent 

maintenance. The air compressor is located in the lower part of the machine. If you need to 

have access to it, you should open the machine body, unscrewing the 4 screws that lock the 

upper cover to the lower box. Never access work on the compressor and never open the 

machine before removing the electrical plug from the socket! Only qualified personnel may 

perform this operation. 

 

 

 

 

Summary of Contents for TP400F

Page 1: ...Owners Manual TP400F NaceCare Solutions 1205 Britannia Road East Mississauga Ontario Canada L4W 1C7 Toll Free 1 800 387 3210 Toll Free Fax 1 800 709 2896 ...

Page 2: ...ockets If an electrical extension cord is used check that it corresponds to the absorbed power of the machine It must be sealed against water SJTW Rated Take care of the cable It is essential that it is protected from water tearing and chemical agents Do not repair the cable if it is damaged replace it with a new one Do not pull the cable to move the machine or to remove the plug from the wall soc...

Page 3: ...he recovery tank used to recover the dirt sucked with the vacuum motor The solution pump and the vacuum motor situated inside the solution tank The control panel for the pump and for the motor The control panel for the compressor and air pressure regulator Preparation for use To prepare the machine for use 1 Insert the male quick disconnect fitting located at the end of the solution hose coming ou...

Page 4: ... open the foam outlet valve 3 Raise the recovery tank after releasing the spring clips holding it to the solution tank 4 Add warm water into the solution tank Add chemical in to the solution tank according to the dilution rate suggested by the manufacturer 5 Re connect the recovery tank to the solution tank ...

Page 5: ...itch to the position I The pump switch is situated on the pump and vacuum motor control panel 8 Switch the air compressor on by moving the switch to the position I The compressor switch is located on the foam regulation control panel The compressor will run until full tank pressure is reached Approx 1 minute After this the compressor motor will only turn on to recharge the tank ...

Page 6: ...efoamer is not used the foam can be sucked in to the vacuum motor and damage it 4 While using the machine if for any reason you should need to switch the compressor on again using the compressor ON OFF switch you must empty the air tank Otherwise the compressor may be unable to start because of the air pressure inside the air tank To empty the air tank spray air only with the foam brush accessory ...

Page 7: ...nctions Wearing parts like carbon brushes bearings etc which must be replaced in time to avoid damage to the other components of the machine can not be then covered by warranty 7 Every 2 3 months drain the air tank by the valve located at the bottom of the air tank Condensation forms in the air tank during normal usage To do this unscrew the circular cover located below the machine locked with 2 s...

Page 8: ...s generated by the machine There are 2 adjustments on the machine 1 Adjusting the air pressure Before making any adjustments you must wait for the compressor to come up to full pressure Foam Consistency For dryer foam you must increase the air pressure For more humid foam you must decrease air pressure NaceCare Solutions 1205 Britannia Road East Mississauga Ontario Canada L4W 1C7 Toll Free 1 800 3...

Reviews: