Nacecare TP400F Owner'S Manual Download Page 2

 

2

 

General Information 

The TP400F is specially designed to clean upholstery, seats and any other fabric surface. 

This machine sprays specially formulated foam on the surface to be cleaned. This foam is 

created by mixing compressed air with water, and chemical. Normal carpet extraction 

methods penetrate below the surface, the only drawback being the long drying time. With the 

TP400F, the foam only cleans the surface. Once the foam is sprayed and vacuumed, drying 

times are minimal in comparison with normal extraction methods. 

 

Safety instructions (read carefully) 

Every electrical device must be used only for the function it is intended for, respecting the 

manufacturer’s instructions. Failure to follow the instructions could result in serious bodily 

injury to the operator (electric shock, electrocution, etc.). Irresponsible use may put people in 

serious danger. Carefully read the following points and be sure to understand everything 

before using the machine. 

 

  Before connecting the machine’s plug to the electrical socket, check that the voltage available 

is the same as indicated on the label of the machine. 

  Verify that the electrical plug complies with the wall outlet. 

  Do not use adapters or multiple sockets 

  If an electrical extension cord is used, check that it corresponds to the absorbed power of the 

machine. It must be sealed against water (SJTW Rated). 

  Take care of the cable. It is essential that it is protected from water, tearing and chemical 

agents. Do not repair the cable if it is damaged replace it with a new one. 

  Do not pull the cable to move the machine or to remove the plug from the wall socket. Pull out 

the plug only when the machine is switched off. 

  Do not handle the plug with wet hands. 

  Do not spray water near outlets. Do not use the machine to spray or to suck corrosive liquids 

(acids or bases), explosive or inflammable liquids (gasoline, kerosene, solvents, etc.) or dust. 

  Do not use the machine in an explosive environment. 

  Do not allow the machine to be used by children and persons unable to understand the danger 

connected with using electrical power. 

  Do not bring the end of the suction hose or one of the accessories near yours or others’ face, 

particularly near ears and eyes: the sucked air could seriously damage them. 

  If the machine is used as a wet vacuum cleaner, you must check the water level in the recovery 

tank regularly to avoid water being sucked in by the vacuum motor. 

  In case of abnormal function (very noisy motor, pump not on, extreme temperature rise, etc.) 

switch the machine OFF and pull out the plug.  

  After use, clean the machine and store it in a warm and dry environment. 

Summary of Contents for TP400F

Page 1: ...Owners Manual TP400F NaceCare Solutions 1205 Britannia Road East Mississauga Ontario Canada L4W 1C7 Toll Free 1 800 387 3210 Toll Free Fax 1 800 709 2896 ...

Page 2: ...ockets If an electrical extension cord is used check that it corresponds to the absorbed power of the machine It must be sealed against water SJTW Rated Take care of the cable It is essential that it is protected from water tearing and chemical agents Do not repair the cable if it is damaged replace it with a new one Do not pull the cable to move the machine or to remove the plug from the wall soc...

Page 3: ...he recovery tank used to recover the dirt sucked with the vacuum motor The solution pump and the vacuum motor situated inside the solution tank The control panel for the pump and for the motor The control panel for the compressor and air pressure regulator Preparation for use To prepare the machine for use 1 Insert the male quick disconnect fitting located at the end of the solution hose coming ou...

Page 4: ... open the foam outlet valve 3 Raise the recovery tank after releasing the spring clips holding it to the solution tank 4 Add warm water into the solution tank Add chemical in to the solution tank according to the dilution rate suggested by the manufacturer 5 Re connect the recovery tank to the solution tank ...

Page 5: ...itch to the position I The pump switch is situated on the pump and vacuum motor control panel 8 Switch the air compressor on by moving the switch to the position I The compressor switch is located on the foam regulation control panel The compressor will run until full tank pressure is reached Approx 1 minute After this the compressor motor will only turn on to recharge the tank ...

Page 6: ...efoamer is not used the foam can be sucked in to the vacuum motor and damage it 4 While using the machine if for any reason you should need to switch the compressor on again using the compressor ON OFF switch you must empty the air tank Otherwise the compressor may be unable to start because of the air pressure inside the air tank To empty the air tank spray air only with the foam brush accessory ...

Page 7: ...nctions Wearing parts like carbon brushes bearings etc which must be replaced in time to avoid damage to the other components of the machine can not be then covered by warranty 7 Every 2 3 months drain the air tank by the valve located at the bottom of the air tank Condensation forms in the air tank during normal usage To do this unscrew the circular cover located below the machine locked with 2 s...

Page 8: ...s generated by the machine There are 2 adjustments on the machine 1 Adjusting the air pressure Before making any adjustments you must wait for the compressor to come up to full pressure Foam Consistency For dryer foam you must increase the air pressure For more humid foam you must decrease air pressure NaceCare Solutions 1205 Britannia Road East Mississauga Ontario Canada L4W 1C7 Toll Free 1 800 3...