GENERAL SAFETY RULES 

 
 

Any use of the machine other than the specified uses different from the instructions written here or 
recommended by NaceCare Solutions is prohibited and could cause bodily harm. 
Do not remove or replace the specification plates on the machine for any reason. 
Before operating the machine or performing maintenance, READ THESE INSTRUCTIONS CAREFULLY. 
The use of the machine in closed surroundings is subordinated to rules effective in your country. 

 

Do not use the machine for applications other than the specified ones. 

 

Do not use the machine to collect acids or toxic materials. 

 

Ensure that work surfaces, slabs, ramps can handle the weight of the machine. 

 

While working, keep a suitable distance from people at work in the same area. 

 

Do not put your hands in the machine while it is operating.  

 

Do not operate the machine with loose clothing, which can get tangled in the disk. 

 

While using the machine, ensure that there is no pieces of rope, cables or other loose debris which 
could get tangled in the brush and harm the machine. 

 

Use only the brushes delivered with the machine or those recommended by NaceCare Solutions. 

 

The use of different brushes is unsafe and could cause bodily harm or serious injury. 

 

The machine must be used by authorized personell trained on these safety rules. 

 

The power socket must have a ground connection  

 

Avoid the power cable while using the machine 

 

If you notice that the power cable is damaged, stop using the machine immediately and have the 
cable replaced by an authorized NaceCare Solutions service centre. 

 

Do not mix chemicals of different brands. 

 

The machine can be stored in temperatures between -25°C and +55°C. 

 

The optimum working temperature of the machine are between 0°C and 40°C. 

 

Humidity % must be within the values 30 to 95%. 

 

Do not use the machine in explosive atmosphere or in presence of powders or flammable liquids. 

 

Do not use acid solutions, which could damage the machine. 

 

The chemical solution must not exceed the temperature of 50°C and each chemical must be used in 
the concentration recommended by the manufacturer. 

 

Avoid keeping the machine in one spot of the floor. This could damage the floor. 

 

In case of fire, use powder extinguisher. 

Do not use water 

 

Do not bump into shelving or scaffoldings with the machie. 

 

When using this machine, the area of use should be blocked off and have signs indicating that the 
floor is wet. 

 

If you experience problems with this machine, bring it to the closest service centre. ONLY a NaceCare 
Solutions service centre is authorized to perform repairs on this machine. 

 

ONLY original spare parts may be used for the repair of this machine. 

 

During regular maintenance of this machine, ensure the power source is disconnected and the proper 
safety precautions are met. 

 

Do not wash the machine with a power washer or hose. Use a damp rag to wipe down the machine. 

 

Do not disconnect the power source while the machine is operating. 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Summary of Contents for NR17

Page 1: ...ANUAL ATTENTION DO NOT USE THE MACHINE WITHOUT HAVING READ THE INSTRUCTIONS NaceCare Solutions 1205 Britannia rd E Mississauga ON Canada L4W 1C7 Tel 1 800 387 3210 Fax 1 800 709 2896 Visit us on the web www nacecare com ...

Page 2: ...ition place its support on the four holes and insert all the screws Insert the four lock nuts M8 in the slots placed under the frame Tighten the bolts one at the time keeping the four lock nuts in the slots Tighten the bolt on the bottom bracket leaving 1 2 mm of space between the two brackets ...

Page 3: ... bracket and lower the top bracket until it is resting on the tank Tighten the bolt on the top bracket with the hand know Connect the handle cable with the motor cable and the solution tube in the suitable hole placed on the left side of the frame ...

Page 4: ...5 MACHINE PREPARATION 6 GENERAL SAFETY RULES 7 WORKING WITH THE MACHINE 8 PREPARING THE MACHINE 8 USING THE MACHINE 8 CHEMICAL DISTRIBUTION 8 ON COMPLETION OF WORK 9 DAILY MAINTENANCE 9 TROUBLE SHOOTING GUIDE 10 INSUFFICIENT WATER 10 THE MACHINE DOES NOT CLEAN EFFICIENTLY 10 THE MACHINE STOPS DURING USE 10 THE MACHINE VIBRATES AND SWINGS 10 ...

Page 5: ...rator The machine is suitable for the use of all sites i e hotels schools hospitals factories shops offices residences The machine can work efficiently only by using it correctly and by maintaining it properly In this manual you will find all of the information necessary to use the machine in the safe and proper ways Please read these instructions carefully Warning the machine can operate only wit...

Page 6: ...ne length INCHES 23 5 25 Machine height motor INCHES 14 14 Machine height handle INCHES 47 47 Brush RPM RPM 154 154 Voltage V 115 115 Motor power W 1100 1100 Frequency Hz 60 60 Weight LBS 88 88 Power cable length FT 50 50 Ø wheels INCHES 7 7 Tank capacity GALLON 4 4 ...

Page 7: ...ent solution keeping the handle in vertical position The detergent solution should not exceed the temperature of 50 C and the detergent must be diluted to the manufacturers specifications WARNING Do not use pure acids Do not mix detergents or acids of different origins BRUSH PAD DRIVER ASSEMBLY WARNING When installing the pad driver brush by hand ensure that the power source is disconnected Instal...

Page 8: ...During use By gently pressing down on the handle the machine shifts towards left Lifting the handle gently the machine shifts towards right WARNING While assembling the brush automatically be sure that there is no one close to the base of the machine WARNING Use only brushes and pad drivers delivered with the machine or recommended by NaceCare Solutions The use of different products may compromise...

Page 9: ...he power cable while using the machine If you notice that the power cable is damaged stop using the machine immediately and have the cable replaced by an authorized NaceCare Solutions service centre Do not mix chemicals of different brands The machine can be stored in temperatures between 25 C and 55 C The optimum working temperature of the machine are between 0 C and 40 C Humidity must be within ...

Page 10: ...own slightly on the handle the machine moves towards left by raising the handle slightly the machine moves towards right MANOEUVRING THE MACHINE Every time the operator uses the machine he she must be confident with the movements of the machine Do not go near other people or obstacles Always Keep the power cable behind the operator Be careful not to work with the machine near the power cable Don n...

Page 11: ...r brush drops off of the machine WARNING DISCONNECT POWER SOURCE BEFORE PERFORMING MAINTENANCE ON THE MACHINE WARNING IF REMOVING THE BRUSH MANUALLY MAKE SURE THE POWER SOURCE IS DISCONNECTED DAILY MAINTENANCE Before storing the machine Examine the power cable for any damage After disconnecting the water hose from the inlet attachment rinse the tank with warm water to clean it out Re install the t...

Page 12: ... be changed when the bristles reach approx 15mm long THE MACHINE STOPS WHILE WORKING Check that the circuit breaker on the rear of the handle has not tripped If the circuit breaker trips repeatedly contact you nearest NaceCare Solutions service centre THE MACHINE VIBRATES AND SWINGS If the machine has been stored in the upright position with the pad brush on it the pad brush may have been deformed...

Reviews: