6
Working method for NEBULIZATION OF A SANITIZING SOLUTION
To spray a nebulized solution, you need to use the spray gun, together with one of the
nebulizing nozzles provided with the machine:
-
the
stainless-steel nozzle
, for a very fine spraying
-
the
brass
nozzle (optional), for a fine spraying
-
the
green
nozzle (optional), for more powerful spraying
Add the chemical in the lower tank
of the machine.
NOTE
: When you spray with one of the above nebulizing nozzles, the machine
will not take
the chemical automatically
from the chemical bottle. The machine will spray the solution
contained in the lower tank. In order to pick up chemicals automatically, it is necessary to
use other nozzles (
the grey nozzle
supplied as standard or
other optional nozzles,
such
as the
red
or
blue
nozzles).
Be sure you use a correct chemical, not damaging the surfaces you are going to treat!
Working method for CLEANING AND SANITIZING SURFACES
The cleaning process is carried out through 4 steps:
A. Solution spraying and chemical action,
B. Rinsing and finishing,
C. Vacuuming the residual of liquid,
D. Washing hard-floor with the injection-extraction system
STEP A
– SOLUTION SPRAYING AND CHEMICAL ACTION
1. Switch on the solution pump, by acting on the pump switch, located on the control panel.
2.
Turn the “solution/rinse” lever in the “solution” position (orange drop ), to allow picking
up the chemical. During solution spraying, the chemical is automatically dosed with a
concentration of about 4%.
3. To spray the solution, press the lever on the accessory. Spray solution uniformly on the
surface to clean, keeping the nozzle of the gun at a distance of about 30-40 cm from the
surface. It is enough to cover the surfaces to be cleaned and sanitized, with a little
quantity of chemical.