Page 13 of 15
1-877-622-2697
WWW
.
NABCOENTRANCES
.
COM
Acusensor 3
____________________________________________________________________________________________
5. Output
Indicator
A LED shows the following conditions.
6. Notice on usage
A. The Acusensor 3 is designed to provide a detection area as close to the
door as possible for maximum coverage. If the Acusensor 3 is installed
on a non-vertical surface, the door may end up inside the detection area.
When installing the Acusensor 3, adjust the detection area so that the
Acusensor 3 does not detect the door.
B. Be sure to unplug the sensor first before changing the detection or mode
settings (If the settings are changed when the power is ON, the Acusen-
sor 3 may malfunction.)
C. Electric power consumption is 100mA (max) at 12VDC per Acusensor 3.
Under low power conditions, the Acusensor 3 may malfunction.
Be certain the power supply used is capable of supplying the necessary
current required for all devices.
DN0359