10700 - 10700 SILVER GREY
RECHARGEABLE CEILING ARMATURE WITH
MOTION SENSOR AND LED’S
Detection range is determined at the temperature of +20°C
“OFFERS ENERGY SAVING FEATURE’’
SETTING
Walking targential to the sensor
(normal detection range)
Walking directly to the sensor
(lower detection range)
Figure 1
[email protected] • www.na-de.com.tr
(e)
(d)
+
-
+
-
SYSTEM COMPONENTS
(a) Glass Cover
(b) Main frame
(c) Mounting holes
(d) Daylight setting nobe
(e) Time setting nobe
(f) Lamp holder (E27 porcelain)
(g) Air-conditioning holes
(h) Battery socket
(a)
(b)
(c)
(c)
(c)
(c)
(g)
(g)
(f)
(e)
(d)
(h)
TROUBLESHOOTING
MALFUNCTION
CAUSE
SOLUTION
• Lamp is off
• There is no
electricity on the
device
• Continuously
lamp is on
• Change perception
area in device
• LED’s do not turn
ON
• Day light adjustment set to
night-time mode during daytime
operate
• Bulb faulty or there is no
connection
• Power switch off or no electricity
• Fuse faulty
• Fuse switch off or fuse faulty
• Connection faulty.
• Continuously movement in
detection zone
• Cars on the streets are being
detected.
• Wind, rain, snow is moving to the
trees & bushes or open windows in
detection zone.
• Sudden temperature changes due
to weather(wind, rain, snow) or the
air expelled from fans.
• Different ambient temperatures.
• There is energy
• No movement
• Battery is low
• Control daylight setting and
re-adjust
• Fit the bulp into the lamp holder,
if it still does not operate, change
the bulb.
• Check the electricity and power
on.
• Change the fuse.
• Check the fuse if necessary use
a new fuse.
• Check the connection cables.
• Check the detection zone.
• Avert it is being detection.
• Change detection zone, change
site of installation.
• Change site of installation or
keep the reasons away.
• Change site of installation.
• Turn of the energy
• Make it see the movement
• Charge battery / Change battery
USAGE AREAS
• In building entrances, stair vestibutes.
• In long halls within the flats.
• In places required within the flats.
• In parking garages.
• In requisite locations within the hotels.
• In schools, hospitals and gas stations
GENERAL SECURITY CAUTIONS
• Take off the original package and control if there is any damage of transportation and general
view of the product.
• Do not use the product at cross purposes.
• Keep it away from water and moist areas.
• Do not use the product at dusty, dirty and rusty places.
• Do not supply high voltage.
• Do not apply any liquid.
• Protect from any stroke.
• Using 230-240V~ voltage is so dangerous that only the specialist electricians must install
and apply.
• 3.6 V rechargeable battery must be used, otherwise it may explode
•
BATTERY IS OUT OF GUARANTY
CAUTIONS FOR INSTALLATION AND USAGE
• Charge the battery 10 hours minimum before operating. Battery will be activated after supply
is off.
• Installing must be carried out professionally in accordance with applicable national wiring and
electrical operating conditions.
• Turn of the network before mounting.
• Do not mount the product near the radiator and moist areas.
• Place the product horizontal to the ceiling.
• Make the ground connection first
• Fix the bulbs before operating.
• Use 6A fuse the supply input.
• Factory setting; daylight adjustment is at the darkest, time adjustment is at the shortest.
• Setting can be made 10 - 15 second after the releasing of the power.
• Time and daylight setting can be made during the day or night.
• Do not change the time and daylight settings abruptly.
• Do not make a second adjustment before you get a result of the first setting of the time and
daylight.
• After you determine the right setting of the daylight, you can arrange the time as you need.
• The best result for the daylight setting can be obtained by adjusting the minimum. And that
you can find the correct setting for sensitivity incrementally.
• When a cleaning needed for the glass, take of carefully and clean with a dry cloth.
• Avoid mounting the detector close to objects that can cause rapid temperature changes such
as heaters, fans, refrigerators and ovents etc, and prevent the detector from point-blank
sunshine.
• It can cause the device operate inaccurately if there is tree, brushes etc. in the coverage
area.
(e) Time setting
Light ON time can be adjusted continuously from “10 sec.
±
1 sec. / 5 min.
±
10 sec.” If you turn
the knob
clockwise
device will operate at minimum time. (10 seconds)
Control dial set to - = Shortest time (10 sec.
±
1 sec.)
Control dial set to + = Longest time (5 min.
±
10 sec.)
(d) Daylight setting
The sensor’s response threshold can be infinitely varied from 2-2000 lux.
If you turn the knob
anticlockwise
device will operate at dark.
Control dial set + = daylight operation approx. 2000 lux.
Control dial set - = night-time operation approx. 2 lux.
NOTE: Device will automatically make its own offset by checking environment for approximately
5 minutes after the first installation. After this period device will operate normally. If you think
the device does not operate normal in first installation, please wait for 5 minutes and start to
test again. Be sure that there is no motion by this period.
DETECTION AREA
Detection area of motion sensors depends on the angle between PIR detector and moving
direction, temperature (power of lamps changes this temperature), mounting style and mounting
place. Temperature is very important for operation for motion sensor like all electronic devices.
Using value of loads higher than written on manuals and packages will increase temprature
inside the device when using Na-De Ceiling Armatures with Motion Sensor. As a result detection
range will decrease and may cause defect of electronic components. Environment temperature
may also cause decrease of detection range. Detection range given is determined at +20°C. If
the weather is hot, it will decrease.
The maximum detection range can be realized when walking tangential to the sensor (figure1)
When walking directly to the sensor detection range will be low. Because you will not be able
to cut vertical areas. The detection distace of 10700 model is 9 m as diameter and 4,5 m as
radius.
GUARANTY
We will remedy defects caused by material flaws or manufacturing faults. The warranty will be
met by repair or replacement at our own discretion. The warranty shall not cover damage to
wear parts, damage or defects caused by improper treatment or maintenance. Further
consequential damage to other object is excluded.
Claims under the warranty will only be accepted if the unit is sent fully assembled and well
packed complete with a brief description of the fault, a receipt or invoice ( date of purchase and
dealer’s stamp) to the appropriate Service Center.
KK-10700_150416_GLB_00
DETECTING RANGE
(L) = Line conductor
(N) = Neutral conductor
( ) = Protective earth conductor
Connect line (L) and neutral (N) to the terminal block.
The bulb must be fixed before the electrical connection.
Battery
socket
2.8 m.
9 m.
4,5 m.
4,5 m.
360°
GB
SPECIFICATIONS
10700
Operating voltage
Detection angle
Mounting height
Detection range
Time settings
Lighting load
Emergency Lighting Load
Battery type
Battery opr. time
Protection class
Opr. temperature
230-240V~ 50/60 Hz
360°
2.8 m.
9 m.
10 sec.
±
1 sec. / 5 min.
±
10 sec.
Max 1x60W E27 bulb
20 lm
3.6V 1000 mAh Rechargeable battery
2 hours
IP20
CLASS 1
-20 °C ~ +40°C
Complies with ROHS Regulation Directive
2002/95/EC
TS EN 60669-2-1