![N-Tron 712FX4 Series User Manual & Installation Manual Download Page 105](http://html1.mh-extra.com/html/n-tron/712fx4-series/712fx4-series_user-manual-and-installation-manual_3184401105.webp)
(Revised 2012-05-01)
Page 105 of 163
CIP – Status
The Status tab under the CIP category will display the CIP status.
The following switch status and partner status information will be shown:
Identity Information:
Product Name: Switch Model Number.
Vendor: This is N-Tron's ODVA EtherNet/IP Vendor ID (1006).
Device Type: The ODVA Device Type is Communications Adapter (= 0x0C hex).
Major Revision: The Major Revision of the CIP implementation.
Minor Revision: The Minor Revision of the CIP implementation.
Serial Number (hex): CIP Serial number, unique across all N-Tron CIP devices. This is the
last 4 octets of the base switch MAC.
Connection Information:
Number of Multicast
Connections:
Current number of CIP Ethernet/IP class 1 (multicast) connections.
Number of Unicast
Connections:
Current number of CIP Ethernet/IP class 3 (unicast) connections.
Summary of Contents for 712FX4 Series
Page 1: ...712FX4 Managed Industrial Ethernet Switch User Manual Installation Guide...
Page 11: ...Revised 2012 05 01 Page 11 of 163 CLEANING Clean only with a damp cloth...
Page 33: ...Revised 2012 05 01 Page 33 of 163 Administration SNMP Continued...
Page 37: ...Revised 2012 05 01 Page 37 of 163 DHCP Server Setup Profiles Continued...
Page 40: ...Revised 2012 05 01 Page 40 of 163 DHCP Server Setup IP Maps Continued...
Page 46: ...Revised 2012 05 01 Page 46 of 163 DHCP Relay Local IP Setup Continued...
Page 52: ...Revised 2012 05 01 Page 52 of 163 Ports Configuration Continued...
Page 82: ...Revised 2012 05 01 Page 82 of 163 IGMP RFilter Continued Modifying rfilter port settings...
Page 90: ...Revised 2012 05 01 Page 90 of 163 N Ring Advanced Configuration Continued...
Page 113: ...Revised 2012 05 01 Page 113 of 163 If a Configuration Device is present that is presented...
Page 149: ...Revised 2012 05 01 Page 149 of 163...