Revision 050908
Page 67 of 101
Configuration – Save or Reset
The Configuration section of web management gives an administrator the ability to save a running
configuration into the NVRAM. This step is needed in order for the switch to remember any changes after a
power cycle.
The “Save” button will save all current changes to the configuration for use after the next power cycle.
The “Reset” button will discard all unsaved changes, reset the switch and load the most recently saved
configuration settings.
The “Factory” button will reload N-Tron’s factory default configuration settings. Doing so will reconfigure
the 700 Series switch to factory defaults. In many cases it is desirable to restore factory defaults but retain
the IP address, subnet mask, and gateway address settings as well as user names and passwords.
Checkboxes are provided to select the desired behavior.