202MC/202MCE HALF DUPLEX SETUP
While all RJ45 port uses Autonegotiation and Autosensing, the 202MC/202MCE Fiber Optic Port is
factory configured for full duplex operation. In the event half duplex operation is desired, follow these
steps:
1.
Remove the Voltage Input Power Plugs.
2.
Remove the top cover (8 screws).
3.
Remove the jumper plug (JP1) from pins 1 and 2.
4.
Replace the top cover.
5.
Proceed with the installation.
Full Duplex = Pins 1 and 2 shorted.
Half Duplex = Remove jumper.
In order to verify the jumper settings have been set correctly, for units which have the
N-View option turned
on
, you should install N-ViewOPC Server software on a PC connected to the LAN. The software is freely
distributed on the ProductCD and our web site (
http://www.n-tron.com/html/opc.html
). Once N-ViewOPC is
installed, you should view the Ports Counter page to remotely monitor each connected port. You may find it
helpful to Copy [Alt]+[PrintScreen] the Port Counter information for each port and Paste [C[V] into a
Windows document for further review. Please consult your N-View OPC Server Manual for additional
information.