CONNECTING THE UNIT 

 

For 10Base-T ports, plug a Category 3 (or greater) twisted pair cable into the RJ45 connector.  For  
100/1000Base-T ports, plug a Category 5e (or greater) twisted pair cable into the RJ45 connector.  Connect 
the  other  end  to  the  far  end  station.    Verify  that  the  LNK  LEDs  are  ON  once  the  connection  has  been 
completed.  To connect any other port to another Switch or Repeater, use a standard Cat5e straight through 
or crossover cable. 
 

Warning:

  Creating a port to port connection on the same switch (i.e. loop) is an illegal operation and will 

create a broadcast storm which will crash the network! 

Alerte: 

Création d'un port de connexion du port sur le même commutateur (c.-à-boucle) est une opération 

illégale et va créer une tempête de diffusion qui va planter le réseau!

 

 

 
 TROUBLESHOOTING 

1.

 

Make sure the   (Power LED) is ON. 

2.

 

Make sure  you  are supplying sufficient  current  for the version chosen.   Note:   The  inrush  current  will 
exceed the steady state current by ~ 2X. 

3.

 

Verify that Link LEDs are ON for both ports. 

4.

 

Verify cabling used between stations.   

5.

 

Verify that cabling is Category 3 or greater for 10Mbit Operation. 

 
 
 
 
SUPPORT 
 

Tel: (251)-342-2164 
FAX: (251)-342-6353 

http://www.n-tron.com

 

[email protected]

 

 
 

Summary of Contents for 1002MC-LX-YY

Page 1: ...Revised 2014 01 23 1 1000 Series Gigabit Media Converter Industrial Gigabit Ethernet Switch User Manual Installation Guide...

Page 2: ...00BaseLX singlemode fiber switch 1003GX2 B Custom mix and match 1003GX2 switch 1005TX 5 port gigabit Ethernet switch Where YY is 10 for 10km max fiber segment length 40 for 40km max fiber segment leng...

Page 3: ...n contained in this document is subject to change without notice N Tron Corporation makes no warranty of any kind with regard to this material including but not limited to the implied warranties of me...

Page 4: ...circuit est sous tension sauf si la zone est connue pour tre non dangereux WARNING Use 110 C or higher rated copper wire 0 22Nm 2 lb in tightening torque for field installed conductors ALERTE Utilisez...

Page 5: ...les during periods of lightning activity ALERTE Ne pas travailler sur le mat riel ou les c bles pendant les p riodes d activit de la foudre WARNING Observe proper DC Voltage polarity when installing p...

Page 6: ...utilize the RJ45 shielded connectors The 1002MC MCE is a two port unmanaged media converter that converts 10 100 1000Base T copper to 1000BaseSX LX full duplex fiber The 1003GX2 GXE2 is a three port...

Page 7: ...G Clean only with a damp cloth INSTALLATION Read the following warning before beginning the installation Lire l avertissement suivant avant de commencer l installation WARNING ALERTE Never install or...

Page 8: ...it snaps into place To remove the unit from the 35mm industrial DIN rail pull forward on the unit until it disengages from the bottom of the DIN rail Rotate the bottom of the unit towards you and up...

Page 9: ...ty LED SPD1000 1000 Speed LED LEDs The table below describes the operating modes LED Color Description ON Power is Applied OFF Power is OFF LNK ACT ON Link established no Activity on cable BLINKING Li...

Page 10: ...lug is 0 5 Nm 0 368 Pound Foot All LEDs will flash ON Momentarily Verify the Power LED stays ON GREEN Note Either V1 or V2 can be connected to power for minimal operation For redundant power operation...

Page 11: ...ve output terminal and the chassis grounding point of the switch As an alternative grounding method both V legs of the power input connector are connected to chassis internally on the PCB Connecting a...

Page 12: ...he same switch i e loop is an illegal operation and will create a broadcast storm which will crash the network Alerte Cr ation d un port de connexion du port sur le m me commutateur c boucle est une o...

Page 13: ...cause harmful interference in which case the user will be required to correct the interference at his own expense INDUSTRY CANADA This Class A digital apparatus meets all requirements of the Canadian...

Page 14: ...ipple Less than 100 mV Input Wire Size 12 24 AWG Environmental Operating Temperature 40 C to 85 C Storage Temperature 40 C to 85 C Operating Humidity 10 to 90 Non Condensing Operating Altitude 0 to 10...

Page 15: ...pprovals Safety For use in Class I Division 2 Groups A B C and D Hazardous Locations UL 508 Industrial Control Equipment ANSI ISA 12 12 01 2007 for use in Class I and II Division 2 and Class III Divis...

Page 16: ...le Less than 100 mV Input Wire Size 12 24 AWG Environmental Operating Temperature 40 C to 85 C Storage Temperature 40 C to 85 C Operating Humidity 10 to 90 Non Condensing Operating Altitude 0 to 10 00...

Page 17: ...pprovals Safety For use in Class I Division 2 Groups A B C and D Hazardous Locations UL 508 Industrial Control Equipment ANSI ISA 12 12 01 2007 for use in Class I and II Division 2 and Class III Divis...

Page 18: ...e Inrush Current 13 Amp 0 61 ms max 24VDC Input Ripple Less than 100 mV Input Wire Size 12 24 AWG Environmental Operating Temperature 40 C to 85 C Storage Temperature 40 C to 85 C Operating Humidity 1...

Page 19: ...d Class III Divisions 1 and 2 Hazardous Classified Locations Groups A B C D T4 cUL C22 2 No 14 M05 cUL C22 2 No 213 M1987 for use in Class I Division 2 Hazardous Locations EMI EN61000 6 4 EN55011 Clas...

Page 20: ...RANTIES EXCLUSIVE IF AN N TRON PRODUCT DOES NOT OPERATE AS WARRANTED ABOVE CUSTOMER S SOLE REMEDY FOR BREACH OF THAT WARRANTY SHALL BE REPAIR REPLACEMENT OR REFUND OF THE PURCHASE PRICE PAID AT N TRON...

Reviews: