background image

13

3 - Machine Maintenance

In order to keep the Speedster® LTD running smoothly 

and reduce the risk of damage to the machine and subse-

quent downtime, Mytee recommends following the mainte-

nance schedule below:

Maintenance Item

Daily

Weekly

Clean and inspect tanks.

X

Clean and inspect hoses.

X

Check and clean internal filters.

X

Check power supply cable.

X

Clean machine with all-purpose 

cleaner and cloth.

X

Check spray nozzles.

X

Flush solution system with Mytee 

System Maintainer.

X

Inspect vacuum hoses for holes and 

loose cuffs.

X

Inspect spray pattern for clogging. 

If clogged, remove spray tips and 

soak them in a recommended liquid 

neutralizer for up to six hours. To 

remove spray tip, twist spray tip 

body counter-clockwise.

X

Lubricate wheels with water 

resistant oil.

X

Inspect machine for water leaks and 

loose hardware.

X

3.1 - Opening the Unit for Maintenance

To open the Speedster® LTD, loosen the rear latches by 

turning them one quarter turn counter-clockwise. Flip the 

latches down and then lift up on the push handle and the 

machine will open up. 

3.2 - Filter Maintenance

The Speedster® LTD comes 

with a nylon mesh bag filter 

that should be placed over 

the pump-out filter on the 

bottom of the recovery 

tank. The nylon bag filter, 

the pump-out filter, and 

the solution filter inside the 

solution tank should be 

checked and cleaned on a 

daily basis. 

3.3 - Ball Float Maintenance

The ball floats in the recovery tank prevent recovered 

dirty water from rising too high and damaging the vacuum 

motors. Clean the mesh screen on the floats regularly. 

3.4 - System Maintainer

Weekly flushing of the solution system with Mytee® 

System Maintainer helps keep lines clean and prevents 

chemical build-up, improving pump life, performance  

and pressure.

How to use System Maintainer:

1.  Mix 1-quart 3601 System Maintainer with 1-quart of 

warm water.

2.  After thoroughly mixing, pour this solution into the 

solution tank.

3.  Turn the pump on FIRST, and run solution through your 

cleaning tool. NOTE: The jet should be removed from 

the cleaning tool in order to prevent clogging due to 

loosening of deposits in line.

4.  Next, turn on the heater (if equipped). If the heater is 

turned on first, it will result in a vapor lock, which will 

affect the machine’s operation.

5.  Next, with both the pump and heater on, begin running 

the solution through the machine. This allows the 

solution to break down any build up in the lines.

6.  After running all of the solution through the machine,  

fill the tank with clean, warm water. Run the water 

through the machine to clear the solution completely 

out of the tank & lines. 

Summary of Contents for Speedster LTD

Page 1: ...Speedster LTD Model LTD3 LTD5 LX LTD12 LTD12 LX User Manual 13655 Stowe Dr Poway CA 92064 P 858 679 1191 F 858 726 6005 REV 1 18 22...

Page 2: ...ecting your machine abusing it or not operating it properly can void its warranty and prevent the machine from performing to the quality and standard you d expect out of the Mytee line If you have any...

Page 3: ...Connecting Vacuum Solution Hoses 10 2 3 Filling the Solution Tank 10 2 4 Switching on the Speedster LTD 10 2 5 Chemical Injection 11 2 6 The Auto Fill Pump Out Features 11 2 7 The Prime Valve 11 2 8 E...

Page 4: ...a plug this wire must be attached to only the grounding pin DO NOT use extension cords Please Note for America use only Parts and Service Please contact Mytee service personnel or a Mytee au thorized...

Page 5: ...sary when used by or near children 11 Do not use in areas where flammable or combustible material may be present 12 Do not leave the unit exposed to harsh weather elements Temperatures below freezing...

Page 6: ...20 amps 115V 60Hz Cord 2 14 amps 115V 60Hz Machine Weight 135 lbs Machine Dimensions 30 x 20 x 42 LTD12 Recovery Tank 11 gallon capacity approx Solution Tank 11 gallon capacity approx Vacuum Motors D...

Page 7: ...7 1 At a Glance 1 2 Included with the Speedster LTD H141V Cuff Lynx 2 Female Cuff Lynx x 1 5 Female Hose H110V Cuff Lynx 2 Female Cuff Lynx x 2 Female Hose H226 Drain Spout...

Page 8: ...l injection meter 11 Front lift handle 12 Quick connect fitting for solution line featuring prime valve 13 2 Cuff Lynx starter 14 Switch plate 15 Recovery tank drain valve 16 Vacuum exhaust ports 17 M...

Page 9: ...ter three position switch not installed on LTD5 and LTD12 5 Heater indicator lights Each light illuminates when the corresponding heater is on not installed on LTD5 and LTD12 6 Dual circuit indicator...

Page 10: ...Primary Cord Vacuum 1 Pump Secondary Cord Vacuum 2 Pump Out LTD12 LX Primary Cord Vacuum 1 Pump Secondary Cord Vacuum 2 Pump Out 2 2 Connecting Vacuum Solution Hoses Use the included Cuff Lynx hose co...

Page 11: ...chemical to siphon into the line Turn the knob until you see the bubble reach the desired gallons per hour of chemical Follow chemical manufacturer s instructions for correct ratio IMPORTANT If chemic...

Page 12: ...ution tank Take the lid off the recovery tank and place the end of the wash hose inside With solution or clean water in the solution tank switch on the pump and turn the prime valve to position 1 show...

Page 13: ...bottom of the recovery tank The nylon bag filter the pump out filter and the solution filter inside the solution tank should be checked and cleaned on a daily basis 3 3 Ball Float Maintenance The ball...

Page 14: ...eed Wand 8400GT Mytee Dry GT Upholstery Tool 8903 Wand Style Spinner 8904 T Handle Spinner 8908 Counter Spinner 8390 EZ 10 Single Jet Wand 8400 4 Stainless Steel Upholstery Tool 8314T Bentley 14 Carpe...

Page 15: ...egularly Drain valve cap is loose and is causing air leakage Tighten the drain valve cap Hose cuffs are loose and causing air leakage Tighten all hose cuffs regularly as may loosen over time Use a glu...

Page 16: ...lace the check valve in unit assembly NEVER OPERATE A UNIT WITHOUT A CHECK VALVE IN PLACE Pump runs for a second then shuts down Possible Causes Solutions QD is pressure locked Relieve pressure from b...

Page 17: ...ring all check out okay there may be a bad switch on the switch plate Running out of hot water too fast Possible Causes Solutions Too much water flowing through the heater Remember when using your mac...

Page 18: ...Mytee LLC 13655 Stowe Dr Poway CA 92064 www mytee com 2022 Mytee LLC Printed in the USA...