MYSON
Décor Radiator Series
System Start-Up & Maintenance
Failure to flush system of debris and flux may cause premature radiator failure, which
can result in leaks and property damage NOT covered under the Myson Warranty.
SYSTEM START-UP
Step 1
Fill and vent the system.
Step 2
Run the system for two (2) hours at full temperature with all radiator valves in the
open position.
Step 3
Shut off and drain the system while the water is still hot.
Step 4
Refill the system.
Step 5
Reheat, vent, and balance the system.
Step 6
Once the Décor Radiator is filled with water the system should be left filled.
Step 7
System should be checked for leaks on seasonal start-ups. Leaks must be repaired
as automatic system fill valves allow fresh water/oxygen into the system attacking
radiators internally.
MAINTENANCE & CLEANING
1
Once operating, avoid the introduction of fresh water and oxygen to the system to
prevent
corrosion.
2
An occasional wiping with a damp cloth using a non-abrasive detergent can protect
the finish of your Myson Décor Panel Radiator.
3
The use of abrasive cleaners will damage the surface of your radiator and void the
manufacturer’s
warranty.
ADDITIVES
Treatment of the primary water is not usually required in a properly designed system.
Treatment may be necessary if either:
1
Local waters are known for their content of corrosive material or if high bacterial levels
are
present.
2
If there is a possibility that the system may be idle during a prolonged period of freezing
temperatures, system should be either drained or protected with antifreeze. If either
corrosion inhibitors or anti-freeze is to be used, it should be added AFTER the system
has been flushed in the final stages. Use only anti-freeze suitable for potable water.
Do not put heating system into operation without checking for leaks with the system up to
full operating temperature. Leaks can appear in a heated system that were not noticeable
with a cold system or air pressure check.
MYSON
1-800-698-9690
948 Hercules Drive
Colchester, VT 05446
Fax: 802-654-7022
MysonInc.com
In accordance with our policy of continual product improvement,
we reserve the right to amend specifications without prior notification
212034-2/12