AC•THOR®9s Assembly Instructions, Version 200910 8
4.
Safety instructions
•
Installation must be carried out by a licensed electrician in
accordance with AS/NZS 3000.
•
For water heating applications compliance with AS/NZS 3500 is
required.
•
Do not open the AC•THOR®9s. The device does not contain any
parts that may be repaired by the user.
•
Only pure resistive electric loads such as immersion heater
elements, boilers, convectors, heating mats or infrared panels can
be connected to the AC•THOR®9s.
•
The loads connected must be suitable for variable supply voltages
between 0-230 V AC (in no circumstances units with electronic
power supply!).
•
All connected devices must be operated with phase and neutral
conductor.
•
Never connect 400 V loads without neutral conductor!
Otherwise this may cause damage to the AC•THOR®9s or to the
other loads connected to it.
•
Only the supplied plugs must be used for connection to the
AC•THOR®9s.
•
Operation of heating systems incorporating electronic thermostats
is not possible.
•
For heating water, only heaters with an integral safety temperature
limiter may be connected.
•
The AC•THOR®9s is designed for fixed installations indoors.
•
Comply with the relevant standards when mounting and
connecting the device.
•
The AC•THOR®9s housing may heat up during operation. Only
mount the unit on non-combustible surfaces.
•
The AC•THOR®9s is only intended for use in dry rooms indoors.
Otherwise there is a risk of fatal electric shock!
•
Installation in rooms with a high level of humidity must comply
with relevant regulations.
Summary of Contents for ESW AC-THOR 9s
Page 6: ...AC THOR 9s Assembly Instructions Version 200910 6 ...
Page 23: ...AC THOR 9s Assembly Instructions Version 200910 23 Power Meter connection without router ...
Page 25: ...AC THOR 9s Assembly Instructions Version 200910 25 Control by inverter or battery management ...
Page 26: ...AC THOR 9s Assembly Instructions Version 200910 26 Control by the energy management system ...
Page 28: ...AC THOR 9s Assembly Instructions Version 200910 28 Operating mode M1 Hot water 3x 3 kW ...
Page 30: ...AC THOR 9s Assembly Instructions Version 200910 30 Operating mode M4 Hot water heat pump ...
Page 31: ...AC THOR 9s Assembly Instructions Version 200910 31 Operating mode M5 Hot water space heating ...
Page 32: ...AC THOR 9s Assembly Instructions Version 200910 32 Operating mode M6 space heating ...