AC•THOR®9s Assembly Instructions, Version 200910 5
2.
Intended use
The electronic AC•THOR®9s Photovoltaic-Power-Manager (in the following,
AC•THOR®9s for short) is designed for operating resistive loads such as
electric immersion heater elements, electric boilers, electric convectors,
electric heating mats or infrared panels. The unit controls the output voltage
according to external signals (temperatures, Ethernet- and other control
signals) linearly and thus the power output of the connected load.
The AC•THOR®9s is controlled by the my-PV Power Meter or can be
combined with products such as inverters of different manufacturers (the
current list of manufacturers can be seen at
pv.com/en/info/compatible-manufacturers .
The AC•THOR®9s is designed for fixed installations indoors.
Installation in rooms with high levels of humidity must comply with the
relevant regulations.
The ACTHOR has an ambient temperature rating of 0°C -40°C. If installed
outdoors it must be able to function within this temperature range and be
located in a shaded position inside an IP55 rated waterproof cabinet which
allows airflow around the unit. Forced ventilation may need to be
installing the unit in an outdoor enclosure.
Any application other than those described above may cause damage.
Furthermore, this may lead to hazards such as a short circuit, fire, electric
shock, etc. The safety instructions and the information on handling in this
manual and in the Operating Instructions must be followed!
The product complies with the statutory, national, and European
requirements. The names of the company and products are trademarks of
my-PV GmbH. All rights reserved.
You will find a comprehensive description of the device’s functions and
settings using the display or via web interface in the Operating Instructions.
Summary of Contents for ESW AC-THOR 9s
Page 6: ...AC THOR 9s Assembly Instructions Version 200910 6 ...
Page 23: ...AC THOR 9s Assembly Instructions Version 200910 23 Power Meter connection without router ...
Page 25: ...AC THOR 9s Assembly Instructions Version 200910 25 Control by inverter or battery management ...
Page 26: ...AC THOR 9s Assembly Instructions Version 200910 26 Control by the energy management system ...
Page 28: ...AC THOR 9s Assembly Instructions Version 200910 28 Operating mode M1 Hot water 3x 3 kW ...
Page 30: ...AC THOR 9s Assembly Instructions Version 200910 30 Operating mode M4 Hot water heat pump ...
Page 31: ...AC THOR 9s Assembly Instructions Version 200910 31 Operating mode M5 Hot water space heating ...
Page 32: ...AC THOR 9s Assembly Instructions Version 200910 32 Operating mode M6 space heating ...