W91.40.622-P
W91.40.623-P
15 |
8. Repairs
Repairs may only be carried out by an authorised
service centre.
9. Recommendations
Caution
!
Only install the pump in a lockable room, out of the reach of
children.
Ensure the motor’s cooling. The installation site must be dry and
well ventilated.
Never obstruct the air supply to the fan by putting any objects on
the pump or too close to the pump.
10. Technical data
Type of motor enclosure
Class of insulation
Motor speed approx. (rpm)
Max. continuous sound pressure
level dB(A)
Max. water temperature (°C)
Max. casing pressure (bar)
IP 55
B/F
2840
70
1)
40 (60)*
2.5
For standard voltage according to DIN IEC 60038 and
DIN EN 60034 (Euro voltage).
Suitable for continuous operation at 1~ 220-240 V
and 3~ Y/Δ 380-420 V / 220-240 V
Tolerances ± 5%
1)
Measured with a phonometer according to DIN 45635.
* Explanation of water temperature 40 (60) °C:
40 °C: max. water temperature as certified by the GS approval.
(60 °C): pump in its current design is however designed for a max. water temperature of 60 °C.
Subject to technical modifications!
Technical Data at 50 Hz
TimeControl 75
TimeControl 100
Inlet Sa / Outlet Da d (mm)
50 / 50
50 / 50
Rec inlet / outlet pipe, PVC-pipe, d
50 / 40
50 / 40
Power input P
₁
(kw)
1~ 230 V
0.50
0.65
Power output P
₂
(kw)
1~ 230 V
0.25
0.40
Rated current (A)
1~ 230 V
2.30
2.90
Weight (kg)
6.60
7.50