4. Installation
Caution
The installation site of the pump must be dry and well ventilated.
When installed in a closed room, a drainage connected to the
sewers must be installed.
The size of the floor drain depends mainly on the size of the
swimming pool and the circulation flow rate but also on possible
leaks within the pool water circulation system.
The ambient temperature must not exceed 40 °C.
Caution
If the pump is installed outside, we recommend providing simple
protection against the weather (rain, sun etc.).
Caution
Implement appropriate measures to attenuate the noise
generated by the pump to avoid damage to the environment.
Fastening the pump to the foundation should be effected
exclusively by means of bolts, threads or dowels, in order to avoid
preventing the removal of the motor unit! Make sure that there is
enough space between the fan cover and the wall, minimum 50
mm. You also need enough space to permit disassembly of the
strainer basket, minimum 210 mm above.
The pump should be installed at water
level or below water level and in a horizontal
position, in order to keep the suction path as
short as possible and to reduce head loss.
The TimeControl is self-priming and should
never be installed more than 2 m above
water level. Make sure that the suction
line is not leaky, otherwise the pump will
prime insufficiently or not at all. We
recommend the installation of check valves
and shut-off valves, according to the type of
pump or plant. The adhesive bonds at the
suction and pressure lines require more
time to cure, allow at least 12 hours before
starting the pump.