TERMINAL BLOCK CONNECTIONS
All the connections must be done without power supply.
EARTH TERMINAL BLOCK CONNECTIONS
Connect the yellow/green network cable and the yellow/green motor cables to earth terminals
A
B C
.
TERMINAL BLOCK 2 CONNECTIONS
1-8
Start control
normally open (NA) for button, key selector, radio receiver or Timer clock connections.
The Start control starts the programmed running cycle.
2-8
Stop control
normally closed (NC). Emergency button.
When pressed the gate stops immediately.
In Opening phase: at the first impulse the gate closes. Break-time: at the first impulse the gate closes
In Closing phase: at the first impulse the gate opens.
If temporarily the Stop contact is not used, link terminal 2 with terminal 8.
3-8
Input of one safety photocell in closing phase.
Input of safety rubber edges and of safety photocell in closing phase.
Input of several safety photocells in closing phase
.
The receiver contacts must be connected in series. Normally closed (NC).
In opening phase: does not work
In closing phase: Stop, break-time for 2 seconds, opening phase again.
If temporarily the photocell contacts are not used, link terminal 3 with terminal 9.
3-9
Input only for safety rubber edges in closing phase.
The contacts must be connected in series if there is more than one safety rubber edge.
Normally closed (NC).
In opening phase: does not work.
In closing phase: Stop, break-time for 2 seconds, opening phase again.
4-8
Input for safety photocells in opening phase (for swing gate).
Normally closed (NC).
In opening phase: Stops until the obstacle has not been removed
In closing phase: Stops and changes direction when the obstacle has been removed
If you also want to connect the safety rubber edges, you must connect in series their contacts with the photocell ones.
If temporarily the photocell contacts are not used, link terminal 4 with terminal 9.
4-9
Input for safety rubber edges in opening phase (for swing gate).
Normally closed (NC).
In opening phase: Stops until the obstacle has not been removed
In closing phase: Stops and changes direction when the obstacle has been removed
The contacts should be connected in series.
7-8
Pedestrian start input
. Normally open (NA).
8-10 Output for photocell receiver power supply.
Output for extra 24V dc accessories power supply.
With all Standard accessories included 100 m A are still available for extra accessories.
9-10 Output for photocell transmitter power supply.
11-12 Blinker intermittent output.
24V 20W max
.
TERMINAL BLOCK 3 CONNECTIONS
eaf that opens firstly and that delays in closing phase.
In case of a gate of one single leaf connect the motor to output
M1
, select parameter on SI, confirm with and save
with push
button C
.
CAPACITOR between terminal 13 and 15
Motor M2
Leaf that opens secondly.
CAPACITOR between terminal 16 and 18
TERMINAL BLOCK 4 CONNECTIONS
Motor M1- output
L
- output
Power input 230-240 Vac - 50/60 Hz. (19=Neutral - 20=phase)
13-14-15
16-17-18
5
P
U
S
19-20
Com.
Com.
Apre
Chiude
13
16
14
17
15
18
M1
M2
24V dc
START
STOP
1
2
3
4
7
8
9
10
11
12
19 20
N
L
Terminal block 2a
Terminal block 2b
Blinker
24V
max
20W
Contact
photo
1
Contact
photo
2
+24
Photo
TX
+24
Photo
RX
Com.
-24
Photo
RX/TX
Pedestrian
Common
Terminal block 3
Terminal block 4
Neutral
Phase
CAPACITOR
CAPACITOR
Open
Closing
AERIAL
RED
BLACK
WHITE
EXTERNAL RADIO PANEL