link terminals 4 - 9

Terminal block 2a

Terminal block 2b

6

CONNECTING PHOTOCELL IN CLOSING PHASE

CONNECTING PHOTOCELL IN OPENING PHASE

link terminals 3 - 9

Terminal block 2a

Terminal block 2b

3 - 9: 

Link terminals 

and

   9 

if the photocells   

are not used in the closing phase.

4 - 9: 

Link terminals

are not used in the opening phase.

 

and

   9

 if   the photocells

 PHOTOCELLS CONNECTIONS

8

= Power supply  + PHOTO RX

9

= Power supply  + PHOTO TX

10

= Power supply  - COM. PHOTO TX/RX

3 - 8

= Photocells connection

 PHOTOCELLS CONNECTIONS

8

= Power supply  + PHOTO RX

9

= Power supply  + PHOTO TX

10

= Power supply  - COM. PHOTO TX/RX

4 - 8

= Photocells connection

 Terminal block 2a

 Terminal block 2b

 Terminal block 2a

 Terminal block 2b

12V dc

12V dc

24V ca

24V dc

24V ca

24V dc

TRA

S

+

+AC 

  -AC

TX

+

-

RX

+AC 

  -AC

24

12V dc

12V dc

24V ca

24V dc

24V ca

24V dc

TRA

S

+

+AC 

  -AC

TX

+

-

RX

+AC 

  -AC

24

CN

MEL

8.8.

7

ELECTRO-LOCK INTERFACE BOARD(MEL)    

      IF YOU WANT TO CONNECT THE 

MEL

 INTO 

CN

• CONNECT THE ELECTRO LOCK
• CHANGE THE PARAMETERS         -        AND 

P0 P I

ELECTRO LOCK

12V 15W

Summary of Contents for Q60A/R

Page 1: ...d 2B wait few seconds and then power the unit again The fuse will be automatically restored Find and remove the short circuit cause before plugging the terminal blocks in 06_gb_utility_2020 A B lower level menu button C button to increase or change to yes si D button to decrease or change to no F1 230V fuse 5A F2 2 1 6 A F3 1 1 6 A F4 24V fuse self restorable 1 6A F5 24V fuse self restorable 0 65A...

Page 2: ...has completely finished the control unit automatically Press buttonA steps thru the top menu until the display shows exits from the sequential programming process and all the working times have Press button B steps thru the sub menu until the display shows been saved Wait until the display shows the currents setting for example Press button C twice until the display shows Press button B repeatedly...

Page 3: ...ot been removed In closing phase Stops and changes direction when the obstacle has been removed If you also want to connect the safety rubber edges you must connect in series their contacts with the photocell ones If temporarily the photocell contacts are not used link terminal 4 with terminal 9 4 9 Input for safety rubber edges in opening phase for swing gate Normally closed NC In opening phase S...

Page 4: ...9 10 12 13 14 15 16 17 18 M1 sx M2 dx M1 dx M1 sx M2 M1 sx dx M1 M2 sx dx BROWN BROWN BROWN BROWN BROWN BROWN BROWN BROWN BLACK BLACK BLACK BLACK BLACK BLACK BLACK BLACK YELLOW GREEN YELLOW GREEN YELLOW GREEN YELLOW GREEN YELLOW GREEN YELLOW GREEN YELLOW GREEN YELLOW GREEN BLUE OR GREY BLUE OR GREY BLUE OR GREY BLUE OR GREY BLUE BLUE BLUE BLUE BLUE OR GREY OR GREY OR GREY OR GREY OR GREY INSIDE IN...

Page 5: ...inal block 3 Terminal block 3 Terminal block 3 Terminal block 3 Terminal block 3 Terminal block 3 Terminal block 3 Terminal block 3 BROWN BROWN BROWN BROWN BROWN BROWN BROWN BROWN BROWN BROWN BROWN BROWN BLACK BLACK BLACK BLACK BLACK BLACK BLACK BLACK BLACK BLACK BLACK BLACK YELLOW GREEN YELLOW GREEN YELLOW GREEN YELLOW GREEN YELLOW GREEN YELLOW GREEN YELLOW GREEN YELLOW GREEN YELLOW GREEN YELLOW ...

Page 6: ...sed in the opening phase 4 and 9 if the photocells PHOTOCELLS CONNECTIONS 8 Power supply PHOTO RX 9 Power supply PHOTO TX 10 Power supply COM PHOTO TX RX 3 8 Photocells connection PHOTOCELLS CONNECTIONS 8 Power supply PHOTO RX 9 Power supply PHOTO TX 10 Power supply COM PHOTO TX RX 4 8 Photocells connection Terminal block 2a Terminal block 2b Terminal block 2a Terminal block 2b 12V dc 12V dc 24V c...