Technical Specifications 

 

CT Inputs: 

3 inputs enable 3-phase or multi-point power       

measurement  

Measurement Range: 

25W to 15kW (50Hz AC, import and export) 

Energy Harvesting Range: 

0.2A to 65A per input phase (Including reactive current) 

Accuracy: 

2.0% Typical 

Transmission Rate: 

1s @ 1A+, <10s @ 0.5-1A, <30s @ <0.5A 

Wireless Interface: 

868 / 915MHz (proprietary protocol) 

Mounting Location: 

Indoor only (can be housed in an IP rated plastic box, if 

required for outdoor installation) 

Dimensions: 

98 x 98 x 36mm 

Operating Temperature: 

-30°C to  +50°C 

 

Technical Support 

If you experience any issues with your 

harvi 

during or post installation, please contact our 

technical support team by scanning the QR Code below 
 

 

 

 

 

 

 

 

https://myenergi.com/support-centre/ 

 

Please contact us directly for the quickest solution 

 

 

Summary of Contents for harvi

Page 1: ... Pioneer Business Park Faraday Way Revision 4 2 June 2022 Stallingborough Lincolnshire England DN41 8FF D3171 harvi Installation Guide Model Number harvi 65A3PR harvi 65A3PR A energy harvesting wireless sensor ...

Page 2: ... or separate power supply are eliminated Step 1 Installation Before you start harvi can be wall mounted harvi can have up to 3 CT s connected Multiple harvi devices can be used on one site Batteries or power supply NOT required 1 Ensure the CT is securely clipped around the cable to be monitored make sure the arrow sticker on the CT is pointing in the direction of normal current flow normally towa...

Page 3: ...D should flash blue once indicating that harvi is on channel 1 However there may be times when the channel may need to changed see Optional Changing Channel 3 Then the LED will flash red to indicate the harvi is in pairing mode 4 First check the myenergi device you are pairing harvi to is set as Master 5 Then select Settings Advanced enter passcode Linked Devices Pairing Mode 6 The harvi should ap...

Page 4: ... configured to use the harvi The function of the CT s connected to the harvi are also configured via the myenergi unit 1 On the myenergi Master device go to Settings Advanced CT config 2 Disable the relevant CT input s for that device this ensures the unit uses the harvi CT instead of a wired CT 3 Then go to Advanced Settings Linked Devices Devices 4 Highlight the harvi device and press or 5 Confi...

Page 5: ...rrent Accuracy 2 0 Typical Transmission Rate 1s 1A 10s 0 5 1A 30s 0 5A Wireless Interface 868 915MHz proprietary protocol Mounting Location Indoor only can be housed in an IP rated plastic box if required for outdoor installation Dimensions 98 x 98 x 36mm Operating Temperature 30 C to 50 C Technical Support If you experience any issues with your harvi during or post installation please contact our...

Reviews: