myenergi
Pioneer Business Park, Faraday Way
Revision 4.2 June 2022
Stallingborough, Lincolnshire, England, DN41 8FF
D3171
Optional:
Changing Channel
The default channel is number 1 and normally this will not need to be changed, however,
there may be a situation where there is some other device causing interference on a
particular channel.
To change channel:
1.
Press and hold the pair button until the LED flashes blue, the LED will flash rapidly to
indicate the current channel number 1 to 8.
2.
To change the channel, press and hold down the button, the current channel will then
cycle from 1 to 8 indicated by the LED. Once the desired channel is indicated,
immediately release the button.
3.
Ensure all other
myenergi
paired devices are set to the same channel. (Settings >
Advanced > “enter passcode” > Linked Devices > Channel
Step 3:
Configuration
After pairing the
harvi
, the
myenergi
device will need to be configured to use the
harvi
. The
function of the CT’s connected to the
harvi
are also configured via the
myenergi
unit.
1.
On the
myenergi
‘Master’ device, go to Settings > Advanced > CT config
2.
Disable the relevant CT input(s) for that device - this ensures the unit uses the
harvi
CT instead of a wired CT.
3.
Then go to “Advanced Settings” > “Linked Devices” > “Devices”
4.
Highlight the
harvi
device and press (
) or (+)
5.
Configure the CT’s according to the installation. Refer to specific manual for the
myenergi
device you are configuring.
6.
If
harvi
is to be used on a 3-phase installation then ensure you set harvi to “three
phase”. This will automatically set all 3 CT inputs to the same input source e.g. grid,
generation etc. If used on 3-phase make sure that the Net Phases setting on your
myenergi
device is turned on
NOTE
If connecting to older
myenergi
devices (those with serial no. starting with a ‘1’) then only
channels 1,3 & 4 can be used, with the exemption of Australian installs.
NOTE
Please ensure you refer to our GOLDEN CT RULES, which can be found in the all
myenergi