8.
Display
1.
Import/Export
Power
The power being either imported or exported from or to the grid (kW). The
direction of the arrows indicate if the property is currently importing power (left)
or exporting power (right)
The size of arrows is proportion to the level of power. When the property is neither
importing or exporting power, the figure will be 0.0kW and there will be no
animated arrows. The property is then said to be 'in balance'.
2.
House Load
Power
The power that the property is currently using in kW.
(Note: This is displayed only when the Generation Sensor is installed directly to a
CT input or a
harvi
or other
myenergi
device.)
3.
Operating
Modes
The current operating mode is displayed here.
4.
Generation
Power
The power being generated at the time in kW.
(Note: This is displayed only when the CTs are installed either hard wired to the CT
inputs of the
eddi
or wirelessly to a
harvi
or other
myenergi
device.)
5.
Date & Time
The current date and time.
6.
Mode Icons
These icons indicate that the import limiting is active (house), Demand Side
Response (~) or the eSense input is live (e).
7.
eddi
Icon
The
eddi
unit. If there are wavy lines above the icon, the unit is thermally limiting!
The output power is temporarily reduced.
8.
Energy Diverted
Today
The accumulated energy that has been sent to the heater(s) today.
9.
Temperature
If the optional Relay & Sensor Board is fitted and temperature probes are installed,
the temperature of the active heater is displayed.
10. Heater Icon
This icon represents the active heater, and next to it is the heater number.
11.
Power Diverting
to Heater
When
eddi
is heating, arrow will show along with the power in kW.
Summary of Contents for eddi 16A1P01H