Page
13
of
24
11.2
Economy Tariff Boosting
Boosting only when economy rate electricity is available can be achieved in one of three ways:
1.
Setting the boost timer to coincide with the economy tariff times. This option should be used only if
the electricity meter is a dual-rate meter (modern meters are usually multi-rate).
2.
Boost only at set times AND if economy rate electricity is available*
3.
Automatically boost whenever the economy tariff rate electricity is available, regardless of the boost
times*
* Options 2 and 3 are available only when using the eSense input on the Relay & Sensor Board. The Relay &
Sensors menu will be available when a Relay & Sensor Board is fitted inside the unit.
For option 2, the eSense Input in the Relay & Sensors menu option should be set to the appropriate Boost
Enable setting. With the Boost Enable function set, the BOOST TIMER screen will include an extra column (see
screenshot on previous page). The e can be toggled on/off, if e is present, the boost will activate only when the
boost times are valid and the economy rate tariff is available.
Alternatively the eSense input can be used to activate the boost whenever the economy tariff rate electricity
is available, regardless of boost times (option 3). To do this, the eSense Input in the Relays & Sensors menu
should be set to Boost 1, Boost 2 or Boost 1&2. When using this option, the Boost Timer is not needed.
11.3
Boost Time Conflicts
Both heaters cannot be active at the same time and so if the boost times are conflicting, the higher priority
heater will take precedence. If one or more boost times conflict for one heater, the boost will follow the latest
time or longest duration.
11.4
Cancelling Boost
The boost can be cancelled by pressing (
) twice during a boost.
11.5
Boost Stop Mode
On occasions where you have Timed Boost Scheduled but you do not want your boost to run i.e. if you are on
holiday, you can put the Boost function in Stop Mode. To do this go to Heater Settings > Stop Mode and press
(
) to stop.
11.5.1
Cancelling Stop Mode
To reactivate your Timed Boost go to Heater Settings > Stop Mode and press (
) to turn off Stop Mode.
12.
Configuration Settings
The more commonly altered settings are described in more detail below.
12.1
Time & Date
The date and time are used for the Boost Timer and the savings calculations and therefore should be set
correctly.
In the event of a power-cut,
eddi
will still keep track of the time and date for a few days, so when power is
restored the clock will not need to be reset.
Time is always in 24-hour format but the date format can be changed.
eddi
will automatically adjust the clock for Daylight Savings Time (DST) as long as Auto DST is enabled and
the correct time zone is selected.