background image

- 5 -

loose fat above the hip on both sides of waist

Celliute removal on belly and back fat

40K cavitation body slimming

Multipolar RF Body skin tightening

Bipolar RF facial wrinkles removal

Dual handles Fat freezing cellulite removal

2.2. Contraindications

The fat freeze machine system is contraindicated for use in patients with:

Patients with acute Severe or cystic acne on the face and/or neck

Malignancy

Patients with Infectious

Pregnant women

Patients with heart

Patients with fever

Patients are receiving operation or those with abnormal body phenomenon

Note : those should be agreed by the professional doctors before using the equipment.

2.3. Precautions

The stand fat freeze machine system has not been evaluated for use over

various materials. Therefore, treatment is not recommended directly over those
areas with any of the following:

Mechanical implants

Dermal fillers

Implanted electrical devices in the face and/or neck

Metal stents in the face and/or neck area

Treatment energy is not recommended for use directly on an existing keloid.
The stand fat freeze machine, system has not been evaluated for use in patients on an
anticoagulant treatment plan

It is recommended that the following areas should be avoided during treatment:

Thyroid gland,thyroid cartilage and trachea

Major vessels

The stand fat freeze machine system has not been evaluated for use in the following
patient populations:

Pregnant or breast feeding women

Children

Summary of Contents for MS-7202F

Page 1: ......

Page 2: ... authorized people in the company It forbids others to change and maintain the machine except the professional people Please contact us if there is any trouble during operation After Sale service We offer ONE YEAR warranty Within warranty period all exchanges or replacement due to defects are free Buyer is responsible for shipping charges If the machine is over warranty please also do not hesitate...

Page 3: ...Patient Safety 5 2 5 Potential Side Effects 6 2 6 Complaints and Adverse Events 6 3 System Overview 6 3 1 System Description 6 3 2 System Components and Features 7 4 System Safety 13 4 1 Electrical and Fire Safety 13 4 2 Equipment Use and Care 14 5 Specification 15 6 Package Listing 15 7 Cleaning and Care 15 7 1 Cleaning the Handpiece 15 7 2 General Care of the System 15 ...

Page 4: ...t the user to information that is of the highest importance and vital to the safety of the patient and user All procedures are broken down by numbered steps Steps must be completed in the sequence they are presented Bulleted lists indicate general information about a particular function or procedure They do not imply a sequential procedure Control names are spelled as they are on the system and th...

Page 5: ...e using the equipment 2 3 Precautions The stand fat freeze machine system has not been evaluated for use over various materials Therefore treatment is not recommended directly over those areas with any of the following Mechanical implants Dermal fillers Implanted electrical devices in the face and or neck Metal stents in the face and or neck area Treatment energy is not recommended for use directl...

Page 6: ...d in the clinical evaluation of the Stand Fat freeze machine system were mild and transient in nature These were limited to Safety no need to take medicine no anesthesia no surgery no trauma immediately following Treatment This typically resolves within a few hours of treatment Pain just touch the fat analyzer will have a sense of uncomfortable frost but soon disappeared Effective 2 to 3 months af...

Page 7: ... area are gently eliminated through the body s normal metabolism process to eliminate unwanted fat 3 1 2 40k Cavitation it is known as cavitation with 40000HZ strong sounds wave Micropore introverted blast inside and outside cell may lead to enhanced molecular motion and a higher energy level and this will finally cause fat cell rupture and thereby achieve the effects of body building and losing w...

Page 8: ... 8 NOTE please fill water before use it here is the way how to fill water in right way ...

Page 9: ...g then pull off or the water will can t fill in machine fill water in Inlet interface when the water overflow from middle interface it indicates water are enough Then close the middle interface pull out the funnel then you can start the machine each time use need fill new water Touch screen interface ...

Page 10: ...u can click in and choose the to 1 Fat freeze vacuum when you choose the cooling function it will in this interface it has two freeze handles and can working at same time before use it please use the fat freeze membranes to protect skin ...

Page 11: ...h body parts it about 25 40 minutes better this button and is for adjust the handle temperature and it can adjust from 5 to 10 also the temperature inside the room also affects the temperature of handles we suggest the 3 5 depending on customer s affordability Home button back to main control interface Stop button Stop working button start stop button 2 Bipolar RF facial wrinkles removal ...

Page 12: ... use on face and it use about 10 15 mins this button is for BIO RF this if for choose the function for RF or BIO of you this head and it depend on the machine model This Machine is RF functions This RF it adopt the 3D smart technology and only touch skin it can light when use it and it s better use the gel with it to full conduct Radio frequency 3 Multipolar RF Body skin tightening ...

Page 13: ... and it can adjust from 0 100 we suggest adjust it from low to high little by little until find a comfortable temperature this heads use on body and it use about 15 20 mins This RF it adopt the 3D smart technology and only touch skin it can light when use it and it s better use the gel with it to full conduct Radio frequency 4 40K cavitation body slimming ...

Page 14: ...ou touch body you can hear the noise like tinnitus it shown the ultrasonic is working this button is for adjust the 40K head time each treatment we suggest about 25 30 mins and use with gel this is choose the ultrasonic model like Continuous or intermittent this button is use for adjust the energy of ultrasonic cavitation 6 Machine design ...

Page 15: ...s it also may design at the back of machine or near screen it depend on machine model 3 2 2 operation detail steps 1 connect the handles with the machine 2 Take the middle plug out or it will not allow fill water 3 then put the funnel in Inlet interface for fill water in the upper one ...

Page 16: ...ct the power Switch on machine 7 Insert the key and rotating right to turn on the machine 8 put one piece anti freeze membrane suit to the treatment area better two pieces 9 once the temperature reach to 5 degree for 3 5minutes 10 Operation details 10 1 THIGH Treated time 25 35 mins Functions help decomposing fatness 10 2 Buttocks Treated time 30 45 mins Recommends Along the muscle of arm pull up ...

Page 17: ...oing tightening gesture after taking treatment for better result 10 4 Abdomen Treated time 25 to 30 minutes From small to large 11 Once completed the treatment Turn off the vacuum Place the handle back and turn off machine 12 Before and after ...

Page 18: ...tem comes with a three conductor AC power cord and plug Use a properly grounded outlet and always plug the system directly into the outlet Never remove the ground conductor or compromise the ground conductor via any AC adapter plugs or extension cords Disconnect the power cord from the outlet by pulling on the plug not the cord Turn off the AC power switch and disconnect the AC power supply before...

Page 19: ...n frostbite the The machine will need fill full water inside before you use it and you need use the Pure water to keep the water cycle When use the cavitation and RF heads it need use with gel on skin The system has no user serviceable components Do not attempt to open the control unit enclosure or transducers Contact mychway Inc if service is required 5 Specification 1 Voltage 220V 50Hz for Europ...

Page 20: ...idelines 1 Periodically replace the water inside the tank to ensure that the water will not be blocked because of impurities 2 Stop suspend the work before changing the handle to ensure it is correct Identifies the handle and extends the life of the system 3 Do not place the handle on a floor or other hard surface This may cause permanent damage 4 Do not twist or pull the sensor cable This may cau...

Page 21: ... 21 ...