Detailed
description
FTR-6-13
29 November 2006
6.3.2 SIZE ADJUSTMENT
* Length adjustment motor (FTR-M4) actually passes the stop position slightly,
reverses slightly pass the point and reverses again for the last time to stop at the
exact position, to take out any play.
Initialization cycle
Main power is switched on.
Length adjustment motor (FTR-M4) starts. The motor (FTR-M4) moves the stop
gate to the smallest booklet size.
The motor (FTR-M4) stops when length adjustment home position switch (FTR-
S11) is activated.
When the switch(FTR-S11) is activated, a counter for the motor (FTR-M4) starts
and the motor (FTR-M4) reverses.
The motor (FTR-M4) runs until* length adjustment motor sensor (FTR-Q12) has
counted the preset amount of pulses set by the paper size and trim length. The
stop gate is now in correct position corresponding to the paper size and trim length
selected.
FTR-S11
FTR-M4 &
FTR-Q12
TRIMMING PROCESS
Summary of Contents for Plockmatic FTR 200
Page 2: ...TRIMMER FTR 200 SERVICE MANUAL 12 February 2007 Subject to change ...
Page 3: ...Page intentionally blank ...
Page 7: ...Page intentionally blank ...
Page 9: ...Page intentionally blank ...
Page 19: ...Page intentionally blank ...
Page 43: ...Page intentionally blank ...
Page 45: ...Page intentionally blank ...
Page 59: ...FTR 4 14 Page intentionally blank ...
Page 61: ...Page intentionally blank ...
Page 65: ...FTR 6 4 29 November 2006 6 1 3 OUTFEED VIEW FTR Q6 FTR M2 FTR M1 ELECTRICAL COMPONENT LIST ...
Page 67: ...Page intentionally blank ...
Page 71: ...Page intentionally blank ...
Page 77: ...Page intentionally blank ...
Page 79: ...Page intentionally blank ...