INSTALLATION

WARNING!

The mixer valve should be fitted only after all the pipework has been installed and ensure no 

pipes or wires are behind where the screws will be required.

Do not modify or use jointing compounds on any of the pipe fittings. Do not solder fittings near 

the mixer valve as heat can damage the valves or seals. Always flush the system prior to install-

ing the valve.

Before installing, make sure the mixer valve is kept in a clean place to prevent any rubbish etc, 

getting into the openings while fitting the pipework.

• 

The mixer valve is suitable for installation on a solid wall, a stud partition wall, dry lined wall 

or fixing to a cubicle or panel.

• 

The water pipes should be securely attached within the wall or panel to support the mixer 

valve and prevent movement or water noise after installation.

• 

The mixer valve hot water inlet has a red symbol next to the inlet and must be on  the left 

hand side with the outlet pointing upwards.

• 

The mixer valve is designed to work at the same hot and cold water pressures. If this is not 

the case a flow controller (disc with small holes) can be fitted to the higher pressure supply 

to the valve. This is best done by testing each one to find out which gives the best results.

• 

The mixer valve will be installed in such a position that the maintenance of the TMV 

and its valves and the commissioning and testing of the TMV can be undertaken.

SITING OF THE MIXER VALVE

Position the mixer valve so that all controls can be comfortably reached while using the shower.

NOTE:  Easily accessible suitable service valves (complying with Water Regulations 

 

Advisory Service www.wras.co.uk). MUST be fitted as close as practical to the valve,

  

on the hot and cold water supplies to the shower as an independent means of  

 

isolating  the water supplies should maintenance or servicing be necessary. These  

 

valves should not restrict the flow.

The supply pipework can be plumbed from above or below but must finish at the suitable 

connections, which should be 155mm centers. If installing into a stud partition etc, the pipework 

will need support. 

Before fitting the mixer valve flush out the pipework in accordance with Water Regulations 

Advisory Service (www.wras.co.uk).

3

Summary of Contents for Atmos Zinc

Page 1: ...Thermostatic Concentric Mixer Valve with Fixed Head Wall Arm Atmos Zinc Thermostatic Concentric Mixer Valve with Fixed Head Wall or Ceiling Arm Customer Care 0845 505 2211 TMV2 Approval property of T...

Page 2: ...8 liters per minute the appliance must be capable of raising the water temperature to a minimum of 52 C The water temperature at the inlet to the mixer valve must remain relatively constant when flow...

Page 3: ...a point not less than 25mm above the spill over level of the relevant bath shower tray or other fixed appliance A double check valve or similar MUST be fitted in the supply pipework to prevent back fl...

Page 4: ...hot and cold water pressures If this is not the case a flow controller disc with small holes can be fitted to the higher pressure supply to the valve This is best done by testing each one to find out...

Page 5: ...th Wall Arm Atmos Zone Concealed Valve with Wall Arm Atmos Zinc Concealed Valve with Ceiling Arm Atmos Zinc Consult the illustration below to make sure you check from the component list that all the p...

Page 6: ...water pressures to hot and cold are the same these disks do not need to be used CONCENTRIC VALVE SET UP 1 Your thermostatic concentric mixer valve is set up in the factory so that a shower hose can be...

Page 7: ...getting into the openings while fitting the pipework You should measure the distance between the outlets on the mixer valve you are fitting to determine the exact distance 3 Complete the fitting of t...

Page 8: ...nnecting the water supplies and checking the connections when running the shower and when the shower is off TRIM PLATE FITTING FOR Atmos Zinc Zone 1 The trim plate is fitted by pushing it onto the mix...

Page 9: ...arm drill a suitable 19mm hole through the wall NOTE When fitting to stud wall a bearer between the uprights maybe required 3 Remove fittings and nuts from end of arm and push arm through wall re fit...

Page 10: ...fit a cross bearer between two joists Drill suitable 19mm hole through ceiling See Fig 23 3 Remove fittings and nuts from end of arm and push arm through wall re fit washer and nut 4 Connect mixed wat...

Page 11: ...ew Then turning the splined shaft clockwise to decrease the temperature colder or anti clockwise to increase the temperature hotter when you have achieved a temperature of 38 C re assemble the tempera...

Page 12: ...the heating system F Hot water supply blocked or restricted G Pressure in excess of max recommended SUGGESTED ACTION Adjust the temperature control this is only a job for a suitably qualified person T...

Page 13: ...Showerhead Reduce simultaneous demand Check stop service valves are fully open Check if enough water pressure Fit reducing disc to outlet of valve Renew flow control cartridge see parts list COMPONEN...

Page 14: ...IT SPARE PARTS Atmos Zinc 1 Fixed Overhead ZLK 2 Wall Arm ZLJ 3 Ceiling Arm ZLI 4 Valve only 36HLW ZLD VALVE SPARE PARTS LIST 5 Fitting Kit 36HLW ZJK 6 Cartridge All in one ZJA 7 Square Cover Plate ZJ...

Page 15: ...14 ACCESSORIES KIT SPARE PARTS Atmos Zone 1 Fixed Overhead ZLS 2 Valve only 36HLW ZLG VALVE SPARE PARTS LIST 3 Fitting Kit 36HLW ZJK 4 Cartridge all in one ZJA 5 Cover Cover Plate ZJV 1 2 3 4 5...

Page 16: ...hout charge provided the product has been properly installed maintained and operated in accordance with the operating instructions This product must not be modified repaired or taken apart except by a...

Page 17: ...5 This guarantee applies to an original installation in accordance to our fitting instructions and does not cover previously installed products showroom displays etc or products that have been moved f...

Page 18: ...our part for death or personal injury resulting from our negligence 4 Except as stated above and to the fullest extent permitted by law all conditions warranties and representations whether express o...

Page 19: ...e on parts or products not supplied as part of the product 4 A charge will be made in the event of a service call aborted by you but not by us or where a call under the terms of guarantee has been boo...

Page 20: ...Cross Limited Trading as The MX Group Alpha Close Delta Drive Tewkesbury Industrial Estate Tewkesbury Glos GL20 8JF www mx group com email mixervalves mx group com Customer Care 0845 505 2211 6752A 0...